Cell activation and thrombin generation in heparin bonded cardiopulmonary bypass circuits using a novel in vitro model
Open Access
- 1 August 1997
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 12 (2) , 268-275
- https://doi.org/10.1016/s1010-7940(97)01208-6
Abstract
OBJECTIVE: It is generally agreed that when the blood contact surfaces of a cardiopulmonary bypass circuit are treated with a layer of heparin molecules the activation of the humoral pathways is attenuated. However, there is still debate as to whether heparin-bonded circuits reduce thrombin generation. This study aims to examine the effects of immobilized heparinon cell activation and thrombin generation in a novel, well controlled model of cardiopulmonary bypass. METHODS: The model used consisted of a heparin-bonded and a non-bonded cardiopulmonary bypass circuit perfused intandem with the same unit of fresh heparinized (3.3 U/ml) human blood for aperiod of 6 h. Samples were taken for analysis from the bag just prior to perfusion and at 30, 60, 120 and 360 min of perfusion. Whole blood was used to analyse platelet and white blood cell count, haematocrit and activated coagulation time. Plasma samples were prepared for batch analysis of the cell activation markers p-selectin, elastase and interleukin-8, and the thrombin generation markers thrombin-antithrombin and prothrombin fragment F1 + 2. A sample of tubing was taken from each circuit at the end of the perfusion and prepared for visualization by scanning electron microscopy. RESULTS: Platelet counts were significantly reduced in the non-bonded circuits compared with the heparin-bonded circuits at 30 (22 versus 200 × 10(9)/L P < 0.01), 60 (26 versus 193 × 10(9)/L P < 0.01) and 120 min (28 versus 193 × 10(9)/L P < 0.01) as were white blood cell counts at 30 (1.5 versus 2.7 × 10(9)/L P < 0.01), 60 (0.9 versus 2.4 × 10(9)/L P< 0.01), 120 (0.9 versus 1.8 × 10(9)/L P < 0.01) and 360 min (0.4versus 0.9 × 10(9)/L P < 0.05). The concentration of p-selectin was found to be significantly higher in the non-bonded circuits than in the heparin-bonded circuits at 30 (37 versus 29 ng/ml P < 0.01), 60 (37 versus 28 ng/ml P < 0.01). 120 (42 versus 27 ng/ml P < 0.01) and at 360 min (72 versus 46 ng/ml P < 0.01). Elastase was elevated in the non-bonded circuits at 30 (570 versus 145 micrograms/l P < 0.01), 60 (646 versus 278 micrograms/l P < 0.01) and 120 min (613 versus 403 micrograms/l P < 0.05) and interleukin-8 at 120 (705 versus 520 pg/ml P< 0.05) and 360 min (11326 versus 9910 pg/ml P < 0.05). A similar picture was found for the thrombin generation markers. Thrombin-antithrombin complexes were raised in the non-bonded circuits compared with heparin-bonded circuits at 60 (24 versus 13 micrograms/l P< 0.05) and 120 min (46 versus 17 micrograms/l P < 0.05) as was prothrombin fragment F1 + 2 at 30 (1.1 versus 0.7 nmol/l P < 0.01), 60(1.3 versus 0.7 nmol/l P < 0.01), 120 (1.8 versus 0.9 nmol/l P <0.01) and 360 min (15.0 versus 13.6 nmol/l P < 0.05). Scanning electron microscopy revealed a greater amount of adherent material on the non-bonded surface relative to the heparin-bonded surface. CONCLUSIONS: In a cardiopulmonary bypass circuit perfused with human blood the activation of platelets and white blood cells has been seen to be significantly reducedin the presence of a heparin-bonded surface. Thrombin generation due to contact activation of the intrinsic coagulation pathway is also reduced.Keywords
This publication has 40 references indexed in Scilit:
- Monitoring of systemic anticoagulation during cardiopulmonary bypassThe Annals of Thoracic Surgery, 1996
- The impact of heparin concentration and activated clotting time monitoring on blood conservationThe Journal of Thoracic and Cardiovascular Surgery, 1995
- Hemostatic complications of cardiopulmonary bypassAmerican Journal of Hematology, 1995
- Heparin-coated circuits reduce activation of granulocytes during cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1992
- Decreased Blood Loss After Cardiopulmonary Bypass using Heparin-Coated Circuit and 50% Reduction of Heparin DoseScandinavian Journal of Thoracic and Cardiovascular Surgery, 1992
- Platelet and neutrophil activation in cardiopulmonary bypassThe Annals of Thoracic Surgery, 1990
- Mechanism of transient adsorption of fibrinogen from plasma to solid surfaces: role of the contact and fibrinolytic systemsBlood, 1988
- Thrombin uptake and inhibition on endothelium and surfaces with a stable heparin coating: A comparative in vitro studyJournal of Biomedical Materials Research, 1986
- Lack of Correlation Between Activated Clotting Time and Plasma Heparin During Cardiopulmonary BypassAnnals of Surgery, 1981
- Heparin therapy during extracorporeal circulationThe Journal of Thoracic and Cardiovascular Surgery, 1975