Dualband spectral‐spatial RF pulses for prostate MR spectroscopic imaging
- 15 November 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 46 (6) , 1079-1087
- https://doi.org/10.1002/mrm.1302
Abstract
Although MR spectroscopic imaging (MRSI) of the prostate has demonstrated clinical utility for the staging and monitoring of cancer extent, current acquisition methods are often inadequate in several aspects. Conventional 180° pulses can suffer from chemical shift misregistration, and have high peak‐power requirements that can exceed hardware limits in many prostate MRSI studies. Optimal water and lipid suppression are also critical to obtain interpretable spectra. While complete suppression of the periprostatic lipid resonance is desired, controlled partial suppression of water can provide a valuable phase and frequency reference for data analysis and an assessment of experimental success in cases in which all other resonances are undetectable following treatment. In this study, new spectral‐spatial RF pulses were developed to negate chemical shift misregistration errors and to provide dualband excitation with partial excitation of the water resonance and full excitation of the metabolites of interest. Optimal phase modulation was also included in the pulse design to provide 40% reduction in peak RF power. Patient studies using the new pulses demonstrated both feasibility and clear benefits in the reliability and applicability of prostate cancer MRSI. Magn Reson Med 46:1079–1087, 2001.Keywords
This publication has 23 references indexed in Scilit:
- Improved water and lipid suppression for 3D PRESS CSI using rf band selective inversion with gradient dephasing (basing)Magnetic Resonance in Medicine, 1997
- Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional press CSI using phase-compensating spectral/spatial spin-echo pulsesJournal of Magnetic Resonance Imaging, 1997
- Pulses with fixed magnitude and variable phase response profilesMagnetic Resonance in Medicine, 1995
- Surface coil MR imaging of the human brain with an analytic reception profile correctionJournal of Magnetic Resonance Imaging, 1995
- Acquisition and quantitation in proton spectroscopyNMR in Biomedicine, 1991
- 1H spectroscopic imaging using a spectral‐spatial excitation pulseMagnetic Resonance in Medicine, 1991
- Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging)IEEE Transactions on Medical Imaging, 1991
- Comparison of single‐shot localization methods (steam and press) for In vivo proton NMR spectroscopyNMR in Biomedicine, 1989
- The application of spinors to pulse synthesis and analysisMagnetic Resonance in Medicine, 1989
- Spatial Localization in NMR Spectroscopy in VivoAnnals of the New York Academy of Sciences, 1987