Reliability and Validity of Arm Volume Measurements for Assessment of Lymphedema
Top Cited Papers
Open Access
- 1 February 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in PTJ: Physical Therapy & Rehabilitation Journal
- Vol. 86 (2) , 205-214
- https://doi.org/10.1093/ptj/86.2.205
Abstract
Background and Purpose. Arm lymphedema following breast cancer surgery is a continuing problem. In this study, we assessed the reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. Subjects. Participants included subjects who had had breast cancer surgery, including axillary dissection—19 with and 22 without a diagnosis of arm lymphedema—and 25 control subjects. Methods. Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatomic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. Results. Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based on anatomic landmarks was lower than that based on distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. Discussion and Conclusion. Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips. [Taylor R, Jayasinghe UW, Koelmeyer L, et al. Reliability and validity of arm volume measurements for assessment of lymphedema. Phys Ther. 2006;86:205–214.]Keywords
This publication has 15 references indexed in Scilit:
- Understanding Lymphoedema and the Occupational Therapist's RoleAustralian Occupational Therapy Journal, 2010
- A Multilevel Cross-Classified Modelling Approach to Peer Review of Grant Proposals: The Effects of Assessor and Researcher Attributes on Assessor RatingsJournal of the Royal Statistical Society Series A: Statistics in Society, 2003
- Upper-Extremity Volume Measurements in Women With Lymphedema: A Comparison of Measurements Obtained Via Water Displacement With Geometrically Determined VolumePTJ: Physical Therapy & Rehabilitation Journal, 2002
- Measurement of upper extremity volume in women after axillary dissection for breast cancerArchives of Physical Medicine and Rehabilitation, 2001
- Lymphedema: current issues in research and managementCA: A Cancer Journal for Clinicians, 2000
- Lymphoedema following surgery for breast cancerBritish Journal of Surgery, 2000
- Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreementJournal of Biomedical Engineering, 1993
- MODERN TREATMENT OF LYMPHOEDEMA I. COMPLEX PHYSICAL THERAPY: THE FIRST 200 AUSTRALIAN LIMBSAustralasian Journal of Dermatology, 1992
- Risk of lymphoedema following the treatment of breast cancerBritish Journal of Surgery, 1986
- Statistical principles in experimental design.Published by American Psychological Association (APA) ,1962