Validation of the Tracmor triaxial accelerometer system for walking
- 1 September 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 33 (9) , 1593-1597
- https://doi.org/10.1097/00005768-200109000-00024
Abstract
LEVINE, J. A., P. A. BAUKOL, and K. R. WESTERTERP. Validation of the Tracmor triaxial accelerometer system for walking. Med. Sci. Sports Exerc., Vol. 33, No. 9, 2001, pp. 1593–1597. Walking is likely to contribute substantially to nonexercise activity thermogenesis. The Tracmor triaxial accelerometer system (Maastricht, The Netherlands) is the most widely validated system for detecting body movement in free-living subjects. The aim of this study was to validate the Tracmor triaxial accelerometer system for estimating the energy expenditure of walking. Experiments were conducted in healthy subjects. First, baseline variability for Tracmor output was determined for subjects standing still. Second, Tracmor output was compared for walking on a treadmill and on level ground. Third, both Tracmor output and energy expenditure were compared for walking on a treadmill and walking on level ground. Finally, the effect of gradient on Tracmor output and energy expenditure was compared for subjects walking on a treadmill. The data demonstrated excellent reproducibility for comparing Tracmor output for standing (CV < 2%). There were excellent log-linear relationships between velocity and Tracmor output walking on a treadmill (r = 0.998) and on level ground (r = 0.999). Tracmor output and the energy expenditure of walking were inseparable for the two modalities of walking. However, the variance in response was such that to reliably derive the relationship between Tracmor output and energy expenditure, separate regression equations are needed for each subject. Finally, the Tracmor accelerometer did not detect the increased energy expenditure of walking that occurs as gradient increases. The Tracmor triaxial accelerometer provides reproducible and reliable data on the body motion associated with walking regardless of whether a subject walks on a treadmill or level ground. Tracmor units can be used to predict the energetic cost of walking provided that separate regression equations are derived for each subject to convert Tracmor output to energy expenditure.Keywords
This publication has 15 references indexed in Scilit:
- Validity of four motion sensors in measuring moderate intensity physical activityMedicine & Science in Sports & Exercise, 2000
- Role of Nonexercise Activity Thermogenesis in Resistance to Fat Gain in HumansScience, 1999
- Physical activity related energy expenditure in children by doubly labeled water as compared with the Caltrac accelerometerInternational Journal of Obesity, 1998
- Gait analysis during treadmill and overground locomotion in children and adultsElectroencephalography and Clinical Neurophysiology/Electromyography and Motor Control, 1997
- Physical activity assessment: comparison between movement registration and doubly labeled water method.Zeitschrift Fur Ernahrungswissenschaft, 1997
- Energy expenditure estimates of the Caltrac accelerometer for running, race walking, and steppingBritish Journal of Sports Medicine, 1997
- A triaxial accelerometer and portable data processing unit for the assessment of daily physical activityIEEE Transactions on Biomedical Engineering, 1997
- Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walkingMedical & Biological Engineering & Computing, 1997
- Daily physical activity assessment: comparison between movement registration and doubly labeled waterJournal of Applied Physiology, 1996
- Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditureMedicine & Science in Sports & Exercise, 1990