Comparison between Radionuclide Ejection Fraction and Fractional Area Changes Derived from Transesophageal Echocardiography Using Automated Border Detection
- 1 September 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 85 (3) , 468-474.
- https://doi.org/10.1097/00000542-199609000-00004
Abstract
Background: Left ventricular fractional area changes (FAC) can be derived from transesophageal echocardiography using an automated border detection system. However, FAC has not yet been compared to left ventricular ejection fraction (EF) evaluated by a reference technique. The aim of this study was to correlate transesophageal echocardiography automated FAC to EF derived from radionuclide angiography to obtain a quantifying method of global left ventricular systolic function at the bedside. Methods: Ten critically ill patients, whose lungs were mechanically ventilated, were included in this prospective study. Patients were scheduled for radionuclide EF evaluation when at least 75% of the endocardium was clearly visualized on transesophageal echocardiography. Patients with esophageal pathology or cardiac dysrhythmia were excluded. Ejection fraction derived from radionuclide angiography was measured using technetium 99m. Echocardiographic data were obtained using an ultrasound system with automated border capabilities. Simultaneous measurements of left ventricular EF and FAC were obtained for each patient, both before and after starting a dobutamine intravenous infusion to modify left ventricular contractility. Results: Mean values for radionuclide EF and transesophageal echocardiography FAC were, respectively: 55% +/- 19% (range 19-89%) and 46% +/- 18% (range 17-80%). Left ventricular EF and FAC were significantly correlated (r = 0.85, SEE = 9.6%). Variations of EF and FAC, induced by dobutamine, were also correlated (r = 0.70, SEE = 4.9%). Conclusions: Fractional area changes determined by transesophageal echocardiography using automated border detection correlate well with radionuclide EF and may be used at the bedside to quantify left ventricular function in selected intensive care unit patients.Keywords
This publication has 24 references indexed in Scilit:
- On-line estimation of changes in left ventricular stroke volume by transesophageal echpcardiographic automated border detection in patients undergoing coronary artery bypass graftingThe American Journal of Cardiology, 1993
- On-Line quantification of left ventricular function by automatic boundary detection and ultrasonic backscatter imagingThe American Journal of Cardiology, 1993
- Quantitation of left ventricular volumes and ejection fraction by biplane transesonhageal echocardiographyThe American Journal of Cardiology, 1993
- Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system.Circulation, 1992
- On-line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imagingJournal of the American College of Cardiology, 1992
- Relationship of Regional Wall Motion Abnormalities to Hemodynamic Indices of Myocardial Oxygen Supply and Demand in Patients Undergoing CABG SurgeryAnesthesiology, 1990
- Comparison of Transesophageal Echocardiographic and Scintigraphic Estimates of Left Ventricular End-Diastolic Volume Index and Ejection Fraction in Patients Following Coronary Artery Bypass GraftingAnesthesiology, 1990
- ESTIMATION OF LEFT VENTRICULAR VOLUME AND EJECTION FRACTION BY TWO-DIMENSIONAL TRANSOESOPHAGEAL ECHOCARDIOGRAPHY: COMPARISON OF SHORT AXIS IMAGING AND SIMULTANEOUS RADIONUCLIDE ANGIOGRAPHYBritish Journal of Anaesthesia, 1990
- Evaluation of Intraoperative Transesophageal Two-dimensional EchocardiographyAnesthesiology, 1987
- Validation of Quantitative Intraoperative Transesophageal EchocardiographyAnesthesiology, 1986