Enzymic flow injection determination of lactose in milk with on-line dialysis
- 1 January 1993
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 118 (7) , 855-858
- https://doi.org/10.1039/an9931800855
Abstract
Milk samples were analysed to determine their lactose content by using flow injection (FI) and incorporating immobilized β-galactosidase and glucose oxidase—mutarotase bioreactors. A dialysis unit was placed after the injection valve to avoid the need for sample pre-treatment. The methodology was based on the chemiluminescence determination of hydrogen peroxide produced by the enzymic reactions, with use of an alkaline reagent containing luminol and hexacyanoferrate(III). Linearity was observed over the concentration range 20–200 mmol l–1 with lactose as standard (r= 0.9995), and 20 milk samples h–1 could be analysed. Comparisons were made with high-performance liquid chromatography and chloramine-T methods. The enzymic FI method afforded a low relative standard deviation (0.49%) and was free from interference. Additionally, the proposed method was simple and did not require precipitation of proteins, or filtration or centrifugation. The enzymic reactors were stable for 6 months when used daily at optimum pH.Keywords
This publication has 10 references indexed in Scilit:
- Flow injection analysis of lactose using covalently immobilized β-galactosidase, mutarotase, and glucose oxidase/peroxidase on a 2-fluoro-1-methylpyridinium salt-activated fractogel supportAnalytical Biochemistry, 1991
- State of the art in on‐line techniques coupled to flow injection analysis FIA/on‐line‐ a critical reviewJournal of Analytical Methods in Chemistry, 1990
- Immobilization of glucose oxidase and peroxidase and their application in flow-injection analysis for glucose in serumApplied Biochemistry and Biotechnology, 1990
- Automated determination of fat, crude protein and lactose in ewe milk by infrared spectrometryThe Analyst, 1986
- Chemiluminescence flow injection analysis determination of sucrose using enzymatic conversion and a microporous membrane flow cellAnalytical Chemistry, 1986
- Determination of glucose in blood by flow injection analysis and an immobilized glucose oxidase columnAnalytica Chimica Acta, 1985
- Galactose determination in an automated flow-injection system containing enzyme reactors and an on-line dialyzerAnalytica Chimica Acta, 1985
- Amperometric Determination of Galactose, Lactose and Dihydroxyacetone Using Galactose Oxidase in a Flow Injection System with Immobilized Enzyme Reactors and On-Line DialysisAnalytical Letters, 1985
- Improved sugar separation by high-performance liquid chromatography using porous microparticle carbohydrate columnsJournal of Chromatography A, 1981
- Continuous-flow monitoring of lactose concentrationBiotechnology & Bioengineering, 1979