Carbon Dioxide Elimination Measures Resolution of Experimental Pulmonary Embolus in Dogs
- 1 August 1996
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 83 (2) , 247-253
- https://doi.org/10.1097/00000539-199608000-00009
Abstract
Patients with severe pulmonary embolism can suffer progressive hypercapnia refractory to supramaximal mechanical ventilation, and may require open-thoracic or transvenous emergency embolectomy in addition to anticoagulation and/or thrombolysis. The functional recovery of gas exchange would be signaled by an increase in pulmonary CO2 elimination and decrease in CO2 retention; such data could guide the course of operative embolectomy. Accordingly, we studied five chloralose-urethane anesthetized, mechanically ventilated dogs with open thoraces in which the right pulmonary arteries (RPAs) were reversibly occluded with cloth snares. After waiting for steady state, we abruptly released the snare to restore RPA perfusion and experimentally simulate resolution of pulmonary embolism. For 70 min we serially measure the CO2 volume exhaled per breath (VCO2,br), arterial, mixed venous, and end-tidal PCO2 (PACO2, PVCO2, PETCO2), cardiac output (QT), and the alveolar dead space fraction (VDalv/VTalv = [PaCO2 - PETCO2/PaCO2). RPA reperfusion caused VCO2,br to significantly and abruptly increase from 8.9 +/- 2.7 to 11.6 +/- 3.6 mL; 70 min later VCO2,br had returned to baseline. PaCO2 and PVCO2 steadily decreased during 70 min of RPA reperfusion. PETCO2 increased from 25 +/- 5 to 33 +/- 5 mm Hg immediately after RPA reperfusion, as VDalv/VTalv decreased from 54% +/- 10% to 32% +/- 12%, but PETCO2 was still significantly greater than baseline at 70 min of RPA reperfusion. QT did not significantly change. We conclude that intraoperative measurement of VCO2,br should immediately detect and follow the resolution of CO2 retention in the lung and peripheral tissues after RPA reperfusion. PETCO2 could not detect the decrease of VCO2,br back to baseline because PETCO2 does not measure exhaled volume or the PCO2 waveform.Keywords
This publication has 25 references indexed in Scilit:
- Pulmonary Physiology during Pulmonary EmbolismChest, 1992
- Can Changes in End-Tidal Pco2 Measure Changes in Cardiac Output?Anesthesia & Analgesia, 1991
- Pulmonary ThromboembolismAnesthesiology, 1990
- Natural Course of Treated Pulmonary EmbolismChest, 1990
- Diagnosis of Pulmonary Embolism Based upon Alveolar Dead Space AnalysisChest, 1989
- Refractory Hypercapnia Complicating Massive Pulmonary EmbolismAmerican Review of Respiratory Disease, 1988
- Irreversible Hypercapnia Secondary to Embolic Occlusion of the Pulmonary ArteryChest, 1984
- Hypercapnia complicating massive pulmonary embolismCritical Care Medicine, 1984
- Immediate Management of Massive Pulmonary EmbolismChest, 1982
- Alveolar Dead Space as an Index of Distribution of Blood Flow in Pulmonary CapillariesJournal of Applied Physiology, 1957