Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique
Open Access
- 1 March 2002
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 88 (3) , 350-356
- https://doi.org/10.1093/bja/88.3.350
Abstract
Background. Cardiac output (CO) can be measured intermittently by bolus thermodilution methods in the pulmonary artery (COpa) or in the aorta (COart). A continuous thermodilution method (CCO) and a method for continuous estimation using the arterial pulse wave (PCCO) are also available. Methods. We compared two methods of intermittent CO measurements in patients during liver transplantation: COpa, regarded as the current clinical standard, and an aortic transpulmonary thermodilution technique (COart) performed with the PiCCO system. We also compared CCO and PCCO. Measurements were made in 62 patients at three stages: after the induction of anaesthesia, after caval clamping phase, and at the end of surgery. We used Bland–Altman and correlation analysis. Results. We found close agreement between the techniques. Mean bias between COart and COpa and PCCO and CCO was 0.15 (2sd of differences between methods=1.74) litre min–1 and –0.03 (1.75) litre min–1, respectively. Mean bias between CCO and COpa and PCCO and COpa was 0.02 (1.48) litre min–1 and 0.04 (1.69) litre min–1, respectively. Conclusions. Measurement with the aortic transpulmonary thermodilution technique gives continuous and intermittent values that agree with the pulmonary thermodilution method. Br J Anaesth 2002; 88: 350–6Keywords
This publication has 27 references indexed in Scilit:
- Editorial: Pulmonary artery catheters - to use or not to use; that is the question?Clinical Intensive Care, 2000
- Continuous Cardiac Output Monitoring During Adult Liver TransplantationAnesthesia & Analgesia, 1997
- Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantationAnaesthesia, 1997
- Semi-continuous versus injectate cardiac output measurement in intensive care patients after cardiac surgeryIntensive Care Medicine, 1996
- Cardiac output measurement in critically ill patients: comparison of continuous and conventional thermodilution techniquesCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1995
- Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?Critical Care Medicine, 1994
- Continuous measurement of cardiac output with the use of stochastic system identification techniquesJournal of Clinical Monitoring and Computing, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The Slowing of Sinus Rhythm during Thermodilution Cardiac Output Determination and the Effect of Altering Injectate TemperatureAnesthesiology, 1985
- Cannulation of big arteries in critically ill patientsCritical Care Medicine, 1985