A comparison of Plasmalyte 148 and 0.9% saline for intra‐operative fluid replacement
Open Access
- 1 September 1994
- journal article
- clinical trial
- Published by Wiley in Anaesthesia
- Vol. 49 (9) , 779-781
- https://doi.org/10.1111/j.1365-2044.1994.tb04450.x
Abstract
Thirty patients undergoing major hepatobiliary or pancreatic surgery were randomly allocated to receive either 0.9% saline or Plasmalyte 148 (a balanced salt solution), at 15 ml.kg‐1.h‐1. Arterial blood gas analysis was performed before and after surgery. Plasma biochemistry (Na+, K+, Cl‐, lactate) measurements were made before and after surgery and at 24 h after surgery. The patients receiving 0.9% saline had significantly increased chloride concentrations (p < 0.01), decreased standard bicarbonate concentrations (p < 0.01) and increased base deficit (p < 0.01) compared to those receiving Plasmalyte 148. There were no significant changes in plasma sodium or potassium or blood lactate concentrations in either group. The exclusive use of 0.9% saline intra‐operatively can produce a temporary hyperchloraemic acidosis which could be given false pathological significance. In addition it may exacerbate an acidosis resulting from an actual pathological stale. The use of a balanced salt solution such as Plasmalyte 148 may avoid these complications.Keywords
This publication has 6 references indexed in Scilit:
- Intraoperative Fluid ManagementSurgical Clinics of North America, 1993
- I.V. FLUIDS DURING SURGERYBritish Journal of Anaesthesia, 1990
- Sepsis syndromeCritical Care Medicine, 1989
- The end of the crystalloid era?Anaesthesia, 1985
- THE POSTOPERATIVE PATIENT AND HIS FLUID AND ELECTROLYTE REQUIREMENTSBritish Journal of Anaesthesia, 1975
- RENAL FUNCTION DURING AND AFTER ANAESTHESIA AND SURGERY: SIGNIFICANCE FOR WATER AND ELECTROLYTE MANAGEMENTBritish Journal of Anaesthesia, 1973