Standard time and frequency generation
- 1 May 1972
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 60 (5) , 493-501
- https://doi.org/10.1109/PROC.1972.8684
Abstract
The basic properties of atomic primary frequency standards are reviewed. A continuously running frequency source combined with counting, storage, and display devices results in a clock. Time scales are obtained by setting clocks with respect to a convenient origin. The accuracy of a primary frequency standard is a combined theoretical and experimental assessment of the uncertainties of all known possible sources of bias from the idealized definition. Recommended standard measures for the stability are the spectral density of fractional frequency fluctuations (frequency domain) and the two-sample no-dead time Allan variance (time domain). The operation of atomic frequency standards is based on various methods of particle interrogation to observe the transitions, particle confinement to obtain sufficient interaction time, and particle preparation to obtain the desired energy level populations. Passive resonator and active oscillator (maser) modes of operation are discussed; the former has some fundamental advantages. A review of the state of the art and current practice shows that cesium beam resonator standards have the best documented accuracy capability (5 × 10-13) and, in their commercial versions, are presently the best available clocks. There are three concepts related to time: time interval, date, and synchronization. In order to assign dates to events, time scales have to be established. The steadily growing need for a very precise and uniform time scale has resulted in a new internationally coordinated time scale, IAT. Frequency metrology will have increasing impact on both length and voltage metrology in the near future.Keywords
This publication has 32 references indexed in Scilit:
- International time and frequency coordinationProceedings of the IEEE, 1972
- Characterization of Frequency StabilityIEEE Transactions on Instrumentation and Measurement, 1971
- HARMONIC MIXING OF MICROWAVE AND FAR-INFRARED LASER RADIATION USING A JOSEPHSON JUNCTIONApplied Physics Letters, 1971
- History of atomic and molecular control of frequency and timePublished by Institute of Electrical and Electronics Engineers (IEEE) ,1971
- Hydrogen Maser Frequency StandardPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1971
- Performance of Newly Developed Cesium Beam Tubes and StandardsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1971
- Cesium Atomic Beam Frequency Standards: A Survey of Laboratory Standards Development from 1949-1971Published by Institute of Electrical and Electronics Engineers (IEEE) ,1971
- Accurate Hamon-Pair Potentiometer for Josephson Frequency-to-Voltage MeasurementsMetrologia, 1970
- ABSOLUTE FREQUENCY MEASUREMENTS OF THE CO2 cw LASER AT 28 THz (10.6μm)Applied Physics Letters, 1970
- Pressure Shift and Broadening of Methane Line at 3.39Studied by Laser-Saturated Molecular AbsorptionPhysical Review Letters, 1969