Mechanical effects of PEEP in patients with adult respiratory distress syndrome
- 1 March 1990
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 68 (3) , 843-848
- https://doi.org/10.1152/jappl.1990.68.3.843
Abstract
In 10 patients with adult respiratory distress syndrome, we studied the effects on respiratory system mechanics of two levels of positive end-expiratory pressure (PEEP), best PEEP (BP) and half of this value (HBP), using a respiratory inductive plethysmograph (RIP) combined with a super syringe. We found the following. 1) Inflation compliance of pressure-volume (PV) curves did not change significantly. 2) End-expiratory volume increased with HBP and further with BP (278 +/- 186 and 464 +/- 313 ml, respectively, P less than 0.01). This increase was positively correlated with inflation compliance for HBP and BP (r = 0.794, P less than 0.01 and r = 0.876, P less than 0.01, respectively). 3) No dynamic hyper-inflation was detected on mechanical ventilation at zero end-expiratory pressure (ZEEP), and the time constant of the respiratory system was in the normal range (0.79 +/- 0.21 s). 4) Hysteresis of PVrip curves, which were corrected for gas exchange, decreased significantly with PEEP (P less than 0.05). We conclude that PEEP does not change inflation PV curve but induces an increase in intrathoracic volume whose magnitude is related to compliance and PEEP level. The reduction of hysteresis with PEEP suggests less gas trapping and thus a functional improvement.This publication has 0 references indexed in Scilit: