Abstract
The hydrogen ion species in a Heliotron E neutral beam injection system of maximum electric power 6.3 MW were analyzed in order to assess the neutral beam power injected into the torus. The maximum proton ratio of the cylindrical bucket type ion source used was observed to be more than 90 percent assuming that the angular divergences for the respective species in the beam are the same. The experimental data are compared with calculations using a particle balance model. The analysis indicates that the net injection power reaches nearly 2.7 MW at the optimal conditions of the system considering the geometrical limitation of the neutral beam path.Keywords
This publication has 3 references indexed in Scilit:
- On the charge state distribution of multiply charged ions extracted from electron beam ion sourcesNuclear Instruments and Methods, 1977
- Intense, mixed-energy hydrogen beams for CTR injectionNuclear Fusion, 1975
- Analysis of the duoplasmatron-type discharge as a source of multiply charged heavy ionsPlasma Physics, 1974