How reliably do rheumatologists measure shoulder movement?
Open Access
- 1 July 2002
- journal article
- clinical trial
- Published by Elsevier in Annals of the Rheumatic Diseases
- Vol. 61 (7) , 612-616
- https://doi.org/10.1136/ard.61.7.612
Abstract
Objective: To assess the intrarater and interrater reliability among rheumatologists of a standardised protocol for measurement of shoulder movements using a gravity inclinometer. Methods: After instruction, six rheumatologists independently assessed eight movements of the shoulder, including total and glenohumeral flexion, total and glenohumeral abduction, external rotation in neutral and in abduction, internal rotation in abduction and hand behind back, in random order in six patients with shoulder pain and stiffness according to a 6×6 Latin square design using a standardised protocol. These assessments were then repeated. Analysis of variance was used to partition total variability into components of variance in order to calculate intraclass correlation coefficients (ICCs). Results: The intrarater and interrater reliability of different shoulder movements varied widely. The movement of hand behind back and total shoulder flexion yielded the highest ICC scores for both intrarater reliability (0.91 and 0.83, respectively) and interrater reliability (0.80 and 0.72, respectively). Low ICC scores were found for the movements of glenohumeral abduction, external rotation in abduction, and internal rotation in abduction (intrarater ICCs 0.35, 0.43, and 0.32, respectively), and external rotation in neutral, external rotation in abduction, and internal rotation in abduction (interrater ICCs 0.29, 0.11, and 0.06, respectively). Conclusions: The measurement of shoulder movements using a standardised protocol by rheumatologists produced variable intrarater and interrater reliability. Reasonable reliability was obtained only for the movement of hand behind back and total shoulder flexion.Keywords
This publication has 16 references indexed in Scilit:
- The reliability of the three-dimensional FASTRAK measurement system in measuring cervical spine and shoulder range of motion in healthy subjectsRheumatology, 2000
- Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotationJournal of Hand Therapy, 1999
- The reproducibility of measurement of shoulder movementActa Orthopaedica, 1999
- OBSERVER VARIABILITY IN MEASURING ELEVATION AND EXTERNAL ROTATION OF THE SHOULDERRheumatology, 1994
- Shoulder joint movement and its relationship to disability in the elderly.1993
- Variability and reliability of joint measurementsThe American Journal of Sports Medicine, 1990
- Decreased Shoulder Range of Motion on Paretic Side After StrokePTJ: Physical Therapy & Rehabilitation Journal, 1989
- Flexibility of the shoulder joint measured as range of abduction in a large representative sample of men and women over 65 years of ageEuropean Journal of Applied Physiology, 1989
- Goniometric Reliability in a Clinical SettingPTJ: Physical Therapy & Rehabilitation Journal, 1987
- Reliability of Goniometric Measurements in Patients with Duchenne Muscular DystrophyPTJ: Physical Therapy & Rehabilitation Journal, 1985