Neuromagnetic field strength outside the human head due to impedance changes from neuronal depolarization
- 1 February 2004
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 25 (1) , 365-378
- https://doi.org/10.1088/0967-3334/25/1/040
Abstract
The holy grail of neuroimaging would be to have an imaging system, which could image neuronal electrical activity over milliseconds. One way to do this would be by imaging the impedance changes associated with ion channels opening in neuronal membranes in the brain during activity. In principle, we could measure this change by using electrical impedance tomography (EIT) but it is close to its threshold of detectability. With the inherent limitation in the use of electrodes, we propose a new scheme based on recording the magnetic field resulting from an injected current with superconducting quantum interference devices (SQUIDs), used in magnetoencephalography (MEG). We have performed a feasibility study using computer simulation. The head was modelled as concentric spheres to mimic the scalp, skull, cerebrospinal fluid and brain using the finite element method. The magnetic field 1 cm away from the scalp was estimated. An impedance change of 1% in a 2 cm radius volume in the brain was modelled as the region of depolarization. A constant current of 100 microA was injected into the head from diametrically opposite electrodes. The model predicts that the standing magnetic field is about 10 pT and changed by about 3 fT (0.03%) on depolarization. The spectral noise density in a typical MEG system in the frequency band 1-100 Hz is about 7 fT, so this places the change at the limit of detectability. This is similar to electrical recording, as in conventional EIT systems, but there may be advantages to MEG in that the magnetic field directly traverses the skull and instrumentation errors from the electrode-skin interface will be obviated.Keywords
This publication has 17 references indexed in Scilit:
- Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changesMagnetic Resonance in Medicine, 2002
- Solving the forward problem in electrical impedance tomography for the human head using IDEAS (integrated design engineering analysis software), a finite element modelling toolPhysiological Measurement, 2001
- Imaging of physiologically evoked responses by electrical impedance tomography with cortical electrodes in the anaesthetized rabbitPhysiological Measurement, 1996
- Design considerations and performance of a prototype system for imaging neuronal depolarization in the brain using 'direct current' electrical resistance tomographyPhysiological Measurement, 1995
- A robust image reconstruction algorithm and its parallel implementation in electrical impedance tomographyIEEE Transactions on Medical Imaging, 1993
- Magnetoencephalography: A tool for functional brain imagingBrain Topography, 1992
- Basic mathematical and electromagnetic concepts of the biomagnetic inverse problemPhysics in Medicine & Biology, 1987
- Cortical steady potential, impedance and excitability changes during and after total ischemia of cat brainExperimental Neurology, 1971
- Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm CurrentsScience, 1968
- MEMBRANE AND PROTOPLASM RESISTANCE IN THE SQUID GIANT AXONThe Journal of general physiology, 1939