Clinical, Angiographic, and Interventional Follow-Up of Patients With Aortic-Saphenous Vein Graft Connectors
- 29 July 2003
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 108 (4) , 452-456
- https://doi.org/10.1161/01.cir.0000080916.84077.c0
Abstract
Background— The use of aortic connectors for proximal saphenous vein bypass graft anastomoses eliminates the need for aortic clamping during coronary artery bypass grafting (CABG) and may reduce the incidence of stroke in the elderly and in patients with severe aortic atherosclerosis. Methods and Results— We studied 74 consecutive patients who received the Symmetry Bypass System aortic connector at the time of CABG. A total of 131 of 144 proximal vein graft anastomoses were performed with this device. The left internal mammary artery was used in 62 patients, and 61 patients had “off-pump” coronary revascularization. A total of 11 patients were readmitted with chest pain consistent with unstable angina 173±39 days after CABG. Five of the 11 patients had previous in-stent restenosis before CABG. At angiography, 20 saphenous vein bypass grafts containing 19 connectors were found to have severe stenosis (n=12) or occlusion (n=6) and were treated with angioplasty and stenting or medical therapy. Seven of 11 patients were readmitted 76±11 days later with recurrent chest pain and were found to have severe stenosis at the previously stented connector site. Six patients underwent angioplasty followed by brachytherapy. Three of these patients redeveloped chest pain and were readmitted 151±71 days later. Two patients were started on oral Rapamune, and one patient underwent redo-CABG. Conclusion— Eleven of 74 patients who received aortic connectors at the time of CABG developed symptomatically significant stenosis or occlusion at the connector site shortly after CABG, requiring multiple repeat interventions, including brachytherapy.Keywords
This publication has 16 references indexed in Scilit:
- The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass graftingThe Journal of Thoracic and Cardiovascular Surgery, 2002
- Facilitated anastomosis for reoperative circumflex coronary revascularization on the beating heart through a left thoracotomyThe Journal of Thoracic and Cardiovascular Surgery, 2002
- Long-term clinical outcome and predictors of major adverse cardiac events after percutaneous interventions on saphenous vein graftsJournal of the American College of Cardiology, 2001
- Are we making progress with percutaneous saphenous vein graft treatment?Journal of the American College of Cardiology, 2001
- Stroke in octogenarians undergoing coronary artery surgery with and without cardiopulmonary bypassThe Annals of Thoracic Surgery, 2000
- Reduced cerebral embolic signals in beating heart coronary surgery detected by transcranial Doppler ultrasound †British Journal of Anaesthesia, 2000
- Safety and efficacy of off-pump coronary artery bypass graftingThe Annals of Thoracic Surgery, 2000
- Procedural results and intermediate clinical outcomes after multiple saphenous vein graft stentingJournal of the American College of Cardiology, 2000
- Stent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass GraftsNew England Journal of Medicine, 1997
- Comparison of Stenting and Balloon Angioplasty for Narrowings in Aortocoronary Saphenous Vein Conduits in Place for More Than FiveYearsThe American Journal of Cardiology, 1997