Adaptation of latex-enhanced assay for percent glycohemoglobin to a Dade Dimension® analyzer
Open Access
- 1 January 1997
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 43 (1) , 76-84
- https://doi.org/10.1093/clinchem/43.1.76
Abstract
At present no method for glycohemoglobin (%HbA1c) is automated on a main-line analyzer to allow joint measurement with other indicators of diabetic control such as glucose and cholesterol. We describe an adaptation of a latex-enhanced competitive immunoassay for quantifying %HbA1c to the Dade International Dimension® analyzer. After a manual hemolysis step, HbA1c and total hemoglobin (Hb) are determined separately. The concentration of glycated β-subunit is obtained from the immunoassay, whereas Hb is assessed colorimetrically from a derivatized form. Both reactions were fully optimized for accuracy, precision, and specificity on the Dimension; stabilities of reagents and calibration were established; and potential interferences were assessed. The analyzer gave reliable results over the required clinical range of 1–15% HbA1c. Within-run and total assay variation were within 5% of the target CV limits, as determined by ANOVA with three representative sample pools across 20 days. Close agreement with an established HPLC procedure and a commercially available enzyme immunoassay was observed for 140 samples from clinically defined patient groups. Additional samples from patients with hemoglobinopathies (n = 20) demonstrated a more complex relationship between methods. We conclude that adaptation of the method for use with the Dimension analyzer is a valid method for quantifying %HbA1c.Keywords
This publication has 29 references indexed in Scilit:
- Glycosylated Hemoglobin and the Risk of Microalbuminuria in Patients with Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1995
- Methods for the Analysis of Glycated Haemoglobins: What is Being Measured?Diabetic Medicine, 1992
- Comparison of the Real‐time Use of Glycosylated Haemoglobin and Plasma Fructosamine in the Diabetic ClinicDiabetic Medicine, 1991
- A rapid and robust particle-enhanced turbidimetric immunoassay for serum β2 microglobulinJournal of Immunological Methods, 1990
- Glycated Haemoglobin and Fructosamine in Non-Diabetic Subjects with Chronic Renal FailureNephrology Dialysis Transplantation, 1990
- Production and characterization of monoclonal antibodies against human glycoalbuminJournal of Immunological Methods, 1989
- Development and validation of a particle-enhanced turbidimetric immunoassay for C-reactive proteinJournal of Immunological Methods, 1987
- The Clinical Information Value of the Glycosylated Hemoglobin AssayNew England Journal of Medicine, 1984
- Genetic and Immunologic Factors in Microvascular Disease in Type I Insulin-Dependent DiabetesDiabetes, 1982
- Glycosylated haemoglobin in renal failureDiabetologia, 1980