For many reasons residue analysis of plant protecting chemicals is becoming of increasing importance. The demand of modern trace analysis techniques is to detect significantly and sensitively values down to levels in the ppb range or even less. Aggravating circumstances are the complex multicomponent sample matrices out of whom the residue analysis has to be performed; theoretically thousands of compounds could be present and interferences with substances of interest are quite likely. One way to get around these difficulties is to employ multidimensional HPLC (MD-HPLC). A method using this invaluable analytical tool tracing Pyridate and its main metabolites in various plant extracts is presented. Based on a brief discussion about requirements of modern trace analysis HPLC in connection with column switching we designed an automatizable setup combining a weak anionexchanger (dimethylamine phase) with a reversed phase system handling relatively large aqueous sample volumes. Depending on specifically described sample pretreatment schemes detection limits down to 30 ppb are routinely obtained. At this level acceptable on-line UV-spectra can be obtained via inserting a spectrophotometric detector in a loop of a 6-port valve. The usefulness of the method described has been demonstrated by analysing several hundred samples.Keywords
This publication has 7 references indexed in Scilit:
- Trace enrichment of polar compounds on chemically bonded and carbonaceous sorbents and application to chlorophenolAnalytical Chemistry, 1981
- Application of column switching in high-performance liquid chromatography to on-line sample preparation for complex separationsJournal of Chromatography A, 1981
- Multidimensional High Performance Liquid ChromatographyJournal of Chromatographic Science, 1980
- Residue analysis by multicolumn liquid chromatography — Herbicides in cerealsChromatographia, 1980
- Möglichkeiten der Vortrennung und Anreicherung im On-Line-Betrieb bei der Hochleistungs-Flüssigkeits-ChromatographieChromatographia, 1980
- Influence of organic modifiers on the rentention behaviour in reversed-phase liquid chromatography and its consequences for gradient elutionJournal of Chromatography A, 1979
- Two-dimensional column liquid chromatographic technique for resolution of complex mixturesJournal of Chromatography A, 1978