Heart Motion-adapted MR Velocity Mapping of Blood Velocity Distribution Downstream of Aortic Valve Prostheses: Initial Experience
- 1 February 2001
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 218 (2) , 548-555
- https://doi.org/10.1148/radiology.218.2.r01ja07548
Abstract
To investigate blood flow velocities and shear rates at two distances downstream of an artificial aortic valve in patients. Blood velocity was quantified downstream of the valve prosthesis (for replacement after aortic valve stenosis or combined stenosis and regurgitation) in 10 patients by using a magnetic resonance (MR) cine velocity mapping method in which the imaging section position is adapted according to the excursion of the valvular plane of the heart. Two acquisitions were performed to display the blood velocity distributions one-fourth valve diameter and one valve diameter downstream of the valve and to quantify blood volumes and shear rates. The velocity profiles measured during flow acceleration one-fourth valve diameter downstream were characterized by a distinct pattern of two lateral jets and one central jet of antegrade flow. High shear rates were found along the leaflet tips. The profiles obtained one valve diameter downstream were skewed, with varying velocity patterns among patients. Peak shear rates were found close to the vessel wall. With correction for through-plane motion of the valve, the mean apparent regurgitant fraction (+/- SD) was 14% +/- 6; the mean regurgitant fraction without correction was 9% +/- 5. The described noninvasive procedure for velocity mapping enables measurements close to the valve and thus evaluation of blood flow patterns with respect to valve design in humans.Keywords
This publication has 23 references indexed in Scilit:
- Motion‐adapted gating based on k‐space weighting for reduction of respiratory motion artifactsMagnetic Resonance in Medicine, 1997
- Prospective navigator correction of image position for coronary MR angiography.Radiology, 1997
- 3D MR angiography of pulmonary arteries using realtime navigator gating and magnetization preparationMagnetic Resonance in Medicine, 1996
- Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary ImagingMagnetic Resonance in Medicine, 1995
- Turbulent Fluctuation Velocity: The Most Significant Determinant of Signal Loss in Stenotic VesselsMagnetic Resonance in Medicine, 1995
- Quantification of regurgitant flow through bileaflet heart valve prostheses: Theoretical and in vitro studiesUltrasound in Medicine & Biology, 1993
- Blood flow measurement using variable velocity encoding in the RR intervalMagnetic Resonance in Medicine, 1993
- Semiautomated method for noise reduction and background phase error correction in MR phase velocity dataJournal of Magnetic Resonance Imaging, 1993
- Quantification of complex flow using MR phase imaging—A study of parameters influencing the phase/velocity relationMagnetic Resonance Imaging, 1992
- Velocity fields and turbulent stresses downstream of biological and mechanical aortic valve prostheses implanted in pigsCardiovascular Research, 1988