Continuous finger arterial pressure: Utility in the cardiovascular laboratory
- 1 March 1991
- journal article
- Published by Springer Nature in Clinical Autonomic Research
- Vol. 1 (1) , 43-53
- https://doi.org/10.1007/bf01826057
Abstract
The clinical utility for autonomic research purposes of the FinapresTM, a device for measuring finger arterial pressure continuously and noninvasively, was assessed by estimating its accuracy, precision and within-subject variability in 48 subjects, aged 18–65 years, in comparison with intraarterial brachial blood pressure. At differences of −3.5 ± 12, −8.0 ± 8 and −4.4 ± 8 mmHg from simultaneous intrabrachial systolic, mean and diastolic pressure, the Finapres meets the Association for the Advan cement of Medical Instruments (AAMI) accuracy requirements for systolic and diastolic, but not for mean pressure. The precision requirements were nearly met for mean and diastolic, but not for systolic pressure. These results compare to those of others under widely varying circumstances in anaesthetized and awake subjects, and are comparable to those published for the auscultatory technique. The within-subject precision of Finapres is high; the 95% confidence intervals are 3.4–4.5 mmHg for systolic, 1.5–2.0 mmHg for mean and 1.7–2.2 mmHg for diastolic. This makes the Finapres suitable for tracking changes in blood pressure. Four case studies are provided as examples of the value of the Finapres in the clinical laboratory.Keywords
This publication has 41 references indexed in Scilit:
- Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlationsJournal of Clinical Monitoring and Computing, 1990
- Sympathetic activity and blood pressure increases with bladder distension in humans.Hypertension, 1989
- Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.Hypertension, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a fingerJournal of Clinical Monitoring and Computing, 1985
- Evaluation of the Penàz servo-plethysmo-manometer for the continuous, non-invasive measurement of finger blood pressureBasic Research in Cardiology, 1984
- Circadian variation of blood pressure in autonomic failure.Circulation, 1983
- Disparities Between Aortic and Peripheral Pulse Pressures Induced by Upright Exercise and Vasomotor Changes in ManCirculation, 1968
- Cardiovascular dynamics during orthostasis and the influence of intravascular instrumentationThe American Journal of Cardiology, 1966
- The digital blood pressure. I. Values in normal subjectsAmerican Heart Journal, 1950