Rapid Readout from Dual Wavelength Spectrophotometers
- 1 January 1972
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 43 (1) , 62-71
- https://doi.org/10.1063/1.1685447
Abstract
Three methods are described for extending the time range of the dual wavelength spectrophotometric technique. First, a dual wavelength system employing interference filters (essentially a differential colorimeter) is described which employs no light modulation and thus gives operation down to the shortest time measurable in view of the system signal‐to‐noise (S/N) ratio. The second method employs dual wavelength light modulation and synchronizes the transient phenomena to the flash of the measuring light. While this method extends the time range down to that obtainable in view of S/N ratio of the optical system it is essentially a single beam method and does not compensate for optical artifacts that occur during a single flash of the measuring light. The third method extends the time range of the dual wavelength method by substituting for the vibrating mirror an air‐turbine‐driven mirror capable of rotating at several kilohertz and giving dual wavelength readout every 400 μsec or less. The three methods have been employed in time ranges of 40, 200, and 1000 μsec, respectively, in the measurement of the fast reaction of oxygen with cytochrome oxidase bound to mitochondrial membranes.Keywords
This publication has 9 references indexed in Scilit:
- A Rapid Scanning Dual Wavelength SpectrophotometerReview of Scientific Instruments, 1971
- Flow flash kinetics of the cytochrome a3-oxygen reaction in coupled and uncoupled mitochondria using the liquid dye laserArchives of Biochemistry and Biophysics, 1971
- Compensation for Light Source Noise in a Sensitive Dual Wavelength SpectrophotometerReview of Scientific Instruments, 1970
- Dual Beam Stopped Flow Spectrophotometer Utilizing Modulated Xenon ArcsReview of Scientific Instruments, 1966
- Double Beam Spectrometer with 10-msec Recording TimeReview of Scientific Instruments, 1964
- ULTRAVIOLET COLOR‐TRANSLATING TELEVISION MICROSCOPYAnnals of the New York Academy of Sciences, 1962
- Regeneration and recirculation of reactants in the rapid-flow apparatus. Part 2.—Practical designsDiscussions of the Faraday Society, 1954
- Rapid and Sensitive Spectrophotometry. II. A Stopped-Flow Attachment for a Stabilized Quartz SpectrophotometerReview of Scientific Instruments, 1951
- Photoelectric Colorimeter for Rapid ReactionsReview of Scientific Instruments, 1942