Sodium Flux in Necturus Proximal Tubule under Voltage Clamp
Open Access
- 1 August 1972
- journal article
- Published by Rockefeller University Press in The Journal of general physiology
- Vol. 60 (2) , 181-201
- https://doi.org/10.1085/jgp.60.2.181
Abstract
Na transport and electrical properties of Necturus renal proximal tubules were analyzed, in vivo, by a voltage clamp method which utilizes an axial electrode in the tubule lumen for passage of current and simultaneous determination of net fluid (or Na) flux by the split droplet method. When the average spontaneous transepithelial potential difference of –8 mv (lumen negative) was reduced to zero by current passage, net Na flux doubled from a mean of 107 to 227 pmoles/cm2 per sec. The relationship between flux and potential over the range –25 to +10 mv was nonlinear, with flux equilibrium at –15 mv and droplet expansion at more negative values. Calculated Na permeability at flux equilibrium was 7.0 x 10–6 cm/sec. Voltage transients, similar to those caused by intraepithelial unstirred layers, were observed at the end of clamping periods. Tubular electrical resistance measured by brief square or triangle wave pulses (2. The epithelial current-voltage relationship was linear over the range –100 to +100 mv, but displayed marked hysteresis during low frequency (<0.04 Hz) triangle wave clamps. The low transepithelial resistance and large opposing unidirectional ion fluxes suggest that passive ionic movements occur across extracellular shunt pathways, while the voltage transients and current-voltage hysteresis are consistent with the development of a local osmotic gradient within epithelium.Keywords
This publication has 19 references indexed in Scilit:
- Limitations of the shrinking-drop micropuncture techniqueAmerican Journal of Physiology-Legacy Content, 1970
- Transtubular movement of albumin in Necturus kidneyAmerican Journal of Physiology-Legacy Content, 1966
- The flow of solute and solvent across a two-membrane systemJournal of Theoretical Biology, 1963
- Platinized Silver Chloride ElectrodeScience, 1962
- Comparison of Short-Circuit Current and Net Water Movement in Single Perfused Proximal Tubules of Rat KidneysNature, 1961
- Measurements of Electrical Potential Differences on Single Nephrons of the Perfused Necturus KidneyThe Journal of general physiology, 1961
- Ionic Permeability and Electrical Potential Differences in Necturus Kidney CellsThe Journal of general physiology, 1961
- Electrical Potential Difference Measurements in Perfused Single Proximal Tubules of Necturus KidneyThe Journal of general physiology, 1961
- Electrical potential measurements on single nephrons of necturusJournal of Cellular and Comparative Physiology, 1958
- Active Transport of Sodium as the Source of Electric Current in the Short‐circuited Isolated Frog Skin.Acta Physiologica Scandinavica, 1951