Scattered radiation in scanning slot mammography
- 1 July 1998
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 25 (7) , 1111-1117
- https://doi.org/10.1118/1.598433
Abstract
Monte Carlo simulations were used to quantify the amount of scattered radiation a scanning slot detector geometry designed for use in digital mammography. Ratios of the scatter to primary (S/P) x-ray photon energy absorbed in the detector were obtained for a Lucite phantom, and were investigated as a function of photon energy, phantom thickness, and slot detector width. Over a Lucite phantom thickness range of 2-6 cm, the S/P ratios range from about 0.10 to 0.17 for a 4 mm wide slot detector at the x-ray photon energies used in mammography. These ratios increased by a factor of approximately 1.8 when the slot width was increased to 10 mm. In general, 20 keV photons gave S/P ratios similar to those of a 30 kVp x-ray spectrum (Mo target + 30 microns Mo filtration). The use of a 3 cm air gap reduced the S/P ratios by a factor of between 2.5 and 3.4, depending on the phantom thickness. For a constant primary energy fluence, coherent scatter was reduced as photon energy increased, whereas Compton scatter increased with increasing photon energy. With no air gap, the contributions of coherent and Compton scatter were found to be equal at 25 keV, whereas the introduction of a 3 cm air gap resulted in equal contributions for the two scatter processes at 36 keV. A 10 mm wide slot detector consisting of a 36.7 mg/cm2 thick Gd2O2S:Tb phosphor screen was compared to an ideal detector absorbing all incident primary/scatter photons. Average differences in the S/P ratios for these two detectors were 7% with no air gap and approximately 4% with a 3 cm air gap. The results obtained in this study will assist in the design of an optimal slot detector for use in digital mammography.Keywords
This publication has 12 references indexed in Scilit:
- Scatter reduction in mammography with air gapMedical Physics, 1996
- Monte Carlo modeling of coherent scattering: influence of interferenceIEEE Transactions on Nuclear Science, 1996
- Performance of glass fiber antiscatter devices at mammographic energiesMedical Physics, 1994
- Design and development of a fiber optic TDI CCD-based slot-scan digital mammography systemPublished by SPIE-Intl Soc Optical Eng ,1993
- The effect of breast composition on absorbed dose and image contrastMedical Physics, 1989
- X-ray diffraction measurements of some plastic materials and body tissuesMedical Physics, 1987
- On the significance of very small angle scattered radiation to radiographic imaging at low energiesMedical Physics, 1983
- Coherent scatter in diagnostic radiologyMedical Physics, 1983
- Experimental measurements of the scatter reduction obtained in mammography with a scanning multiple slit assemblyMedical Physics, 1981
- The Intensity of Scattered Radiation in MammographyRadiology, 1978