Characterization of synthetic nucleic acids by electrospray ionization quadrupole time‐of‐flight mass spectrometry
- 26 May 2005
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 40 (7) , 932-945
- https://doi.org/10.1002/jms.870
Abstract
The potential of electrospray ionization quadrupole‐quadrupole‐time‐of‐flight mass spectrometry (ESI‐QqTOF‐MS) for the characterization of synthetic nucleic acids was evaluated. Oligonucleotides ranging in size from 12 up to 51 nucleotides were analyzed via direct infusion MS as well as via liquid chromatography (LC) online hyphenated to MS. These experiments proved the outstanding mass spectrometric performance of the TOF mass analyzer in regard of accuracy, reproducibility, resolution, and sensitivity. During a 1‐min run, the monoisotopic mass of (dT)24was measured with a maximum relative mass deviation of 7.64 ppm proving the high mass accuracy of the TOF analyzer. Over a period of 1 h, mean deviations were determined in the range between −3.58 ppm and 3.06 ppm demonstrating the high stability of the applied external calibration. The molecular mass of a 51‐mer was measured with a deviation smaller than 3.23 ppm from the theoretical value. The resolution exceeded a value of m/Δm = 20 000 (m is the measured mass and Δm the full peak width at half‐maximum), which enabled the separation of the isotopic peaks of all investigated oligonucleotides. Because of the outstanding transmission and detection efficiency of the TOF mass analyzer, detection limits in the amol/µl to low fmol/µl range were reached. The usability of LC‐ESI‐QqTOF‐MS for the qualitative and quantitative analysis of synthetic oligonucleotide mixtures was demonstrated. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 64 references indexed in Scilit:
- Proofreading Activity of Pfu Thermostable DNA Polymerase on a 6-O-Methylguanine-Containing Template Monitored by ESI-FTICR Mass SpectrometryChemBioChem, 2004
- Determination of a correction to improve mass measurement accuracy of isotopically unresolved polymerase chain reaction amplicons by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometryRapid Communications in Mass Spectrometry, 2003
- Effect of instrument tuning on the detectabilityof biopolymers in electrospray ionization mass spectrometryJournal of Mass Spectrometry, 2003
- Electrospray ionization quadrupole time-of-flight mass spectrometry and quadrupole mass spectrometry for genotyping single nucleotide substitutions in intact polymerase chain reaction products in K-ras and p53Rapid Communications in Mass Spectrometry, 2002
- Accurate mass measurement of DNA oligonucleotide ions using high-resolution time-of-flight mass spectrometryJournal of Mass Spectrometry, 2002
- Matrix-assisted ultraviolet laser desorption of non-volatile compoundsPublished by Elsevier ,2001
- Comparison of direct infusion and on-line liquid chromatography/electrospray ionization mass spectrometry for the analysis of nucleic acidsJournal of Mass Spectrometry, 2000
- High Sensitivity Collisionally-activated Decomposition Tandem Mass Spectrometry on a Novel Quadrupole/Orthogonal-acceleration Time-of-flight Mass SpectrometerRapid Communications in Mass Spectrometry, 1996
- Reflecting time-of-flight mass spectrometer with an electrospray ion source and orthogonal extractionAnalytical Chemistry, 1994
- Electrospray ion source. Another variation on the free-jet themeThe Journal of Physical Chemistry, 1984