Intensity-based 2-D-3-D registration of cerebral angiograms
- 3 November 2003
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 22 (11) , 1417-1426
- https://doi.org/10.1109/tmi.2003.819283
Abstract
We propose a new method for aligning three-dimensional (3-D) magnetic resonance angiography (MRA) with 2-D X-ray digital subtraction angiograms (DSA). Our method is developed from our algorithm to register computed tomography volumes to X-ray images based on intensity matching of digitally reconstructed radiographs (DRRs). To make the DSA and DRR more similar, we transform the MRA images to images of the vasculature and set to zero the contralateral side of the MRA to that imaged with DSA. We initialize the search for a match on a user defined circular region of interest. We have tested six similarity measures using both unsegmented MRA and three segmentation variants of the MRA. Registrations were carried out on images of a physical neuro-vascular phantom and images obtained during four neuro-vascular interventions. The most accurate and robust registrations were obtained using the pattern intensity, gradient difference, and gradient correlation similarity measures, when used in conjunction with the most sophisticated MRA segmentations. Using these measures, 95% of the phantom start positions and 82% of the clinical start positions were successfully registered. The lowest root mean square reprojection errors were 1.3 mm (standard deviation 0.6) for the phantom and 1.5 mm (standard deviation 0.9) for the clinical data sets. Finally, we present a novel method for the comparison of similarity measure performance using a technique borrowed from receiver operator characteristic analysis.Keywords
This publication has 18 references indexed in Scilit:
- Fusing speed and phase information for vascular segmentation of phase contrast MR angiogramsMedical Image Analysis, 2002
- Retrospective intermodality registration techniques for images of the head: surface-based versus volume-basedIEEE Transactions on Medical Imaging, 1999
- A comparison of similarity measures for use in 2-D-3-D medical image registrationIEEE Transactions on Medical Imaging, 1998
- Real-time registration of 3D cerebral vessels to X-ray angiogramsPublished by Springer Nature ,1998
- 3D/2D registration via skeletal near projective invariance in tubular objectsPublished by Springer Nature ,1998
- Multimodality image registration by maximization of mutual informationIEEE Transactions on Medical Imaging, 1997
- Registration of head volume images using implantable fiducial markersIEEE Transactions on Medical Imaging, 1997
- Multi-modal volume registration by maximization of mutual informationMedical Image Analysis, 1996
- Retrospective registration of X-ray angiograms with MR images by using vessels as intrinsic landmarksJournal of Magnetic Resonance Imaging, 1994
- Real-time distortion correction of digital X-ray II/TV-systems: an application example for Digital Flashing Tomosynthesis (DFTS)The International Journal of Cardiovascular Imaging, 1990