Auger electron spectroscopic studies of stainless-steel implants
- 30 June 1985
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 19 (6) , 663-671
- https://doi.org/10.1002/jbm.820190606
Abstract
Auger electron spectroscopy together with scanning electron microscopy has been used to study the interface between stainlesssteel implants and human tissue. The thickness and nature of the oxide layer on the implants have been found to depend on the location of the implants in the body. Before implantation, the oxide layer is about 50 Å thick, consisting mainly of chromium oxide. For implants located in cortical bone the thickness of the interfacial oxide layer remains unaffected, while it increases by a factor of three to four on samples located in bone marrow. In both these cases calcium and phosphorus are incorporated in the oxides. Implants located in soft tissue have an interfacial oxide layer with a thickness of about one and one‐half times that on an unimplanted sample. On these samples, calcium and phosphorus are not found, but occasionally sulfur is found in the oxide layer. All these samples originated from the oral region of the body; the reason for this finding, however, is not known at present time. The interactions between the implants and human tissues resulting in the observed changes of the implant surfaces are discussed in terms of oxygen pressures and metabolic activity.This publication has 9 references indexed in Scilit:
- ESCA Studies of heparinized and related surfacesJournal of Colloid and Interface Science, 1983
- Electron Microscopic Analysis of the Bone-Titanium InterfaceActa Orthopaedica, 1983
- Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in ManActa Orthopaedica, 1981
- An interpretation of the Auger LVV transitions from oxides of third-row elementsJournal of Electron Spectroscopy and Related Phenomena, 1977
- Corrosion of Implant MaterialsAnnual Review of Materials Science, 1976
- Simultaneous determination of blood flow in cortical bone, marrow, and muscle in canine hind leg by femoral artery catheterizationCalcified Tissue International, 1974
- Auger electron spectroscopy study of 18/8 stainless steel oxidationJournal of Electron Spectroscopy and Related Phenomena, 1974
- Determination of Cortical Blood Flow in Rabbit Femur by Radioactive MicrospheresActa Physiologica Scandinavica, 1970
- BLOOD FLOW RATES IN COMPACT AND CANCELLOUS BONE AND BONE MARROW1967