Acute Hemodynamic Effects of Atrioventricular Pacing at Differing Sites in the Right Ventricle Individually and Simultaneously
- 1 April 1997
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 20 (4) , 909-915
- https://doi.org/10.1111/j.1540-8159.1997.tb05493.x
Abstract
We hypothesized that pacing, which provided a rapid uniform contraction of the ventricles with a narrower QRS, would produce a better stroke volume and cardiac output (CO). We sought to study whether pacing simultaneously at two sites in the right ventricle (right ventricular apex and outflow tract) would provide a narrower QRS and improved CO in 11 patients undergoing elective electrophysiology studies. Patients were studied by transthoracic echocardiography measurement of CO using the Doppler flow velocity method in normal sinus rhythm, AOO pacing (rate 80), DOO pacing in the right ventricular apex (AV delay 100 ms). DOO pacing in the right ventricular outflow tract, and DOO pacing at both right ventricular sites simultaneously in random order. The COs were 5.42 ± 1.83, 5.61 ± 1.97. 5.67 ± 1.6. 5.84 ± 1.68. and 5.86 ± 1.52 L/min, respectively (no significant difference by repeated measures analysis of variance [ANOVA]). The QRS durations were 0.09 ± 0.02, 0.09 ± 0.02. 0.13 ± 0.027, 0.13 ± 0.03, and 0.11 ± 0.03 sees respectively. Repeated measures ANOVA showed that the QRS duration significantly increased with right ventricular apex or right ventricluar outflow tract pacing compared to sinus rhythm and AOO pacing (P < 0.001) but then diminished with pacing at both sites (P < 0.01). QRS duration was not correlated with CO, however the change in QRS duration correlated significantly with the change in CO when pacing was performed at the two right ventricular sites simultaneoasly. In conclusion, during DOO pacing, there was a trend for pacing in the right ventricular outflow tract or both sites to improve the CO compared to the right ventricular apex. With simultaneous pacing at both ventricular sites, the QRS narrowed. Further studies will be required to see if this approach has value in patients with poor left ventricular function or congestive heart failure.Keywords
This publication has 8 references indexed in Scilit:
- 740-1 Septal Pacing Improves Single Chamber-paced Left Ventricular Function: A Comparative Evaluation with Atrial and Apical PacingJournal of the American College of Cardiology, 1995
- Four Chamber Pacing in Dilated CardiomyopathyPacing and Clinical Electrophysiology, 1994
- Septal Short Atrioventricular Delay Pacing: Additional Hemodynamic Improvements in Heart FailurePacing and Clinical Electrophysiology, 1994
- Long-term efficacy of physiologic dual-chamber pacing in the treatment of end-stage idiopathic dilated cardiomyopathyThe American Journal of Cardiology, 1992
- Effects of dual-chamber pacing with short atrioventricular delay in dilated cardiomyopathyThe Lancet, 1992
- Comparison of Intrinsic Versus Paced Ventricular FunctionPacing and Clinical Electrophysiology, 1992
- Impact of dual-chamber permanent pacing in patients with obstructive hypertrophic cardiomyopathy with symptoms refractory to verapamil and beta-adrenergic blocker therapy.Circulation, 1992
- Relative importance of activation sequence compared to atrioventricular synchrony in left ventricular functionThe American Journal of Cardiology, 1991