Theoretical noise model for oxygenation‐sensitive magnetic resonance imaging
Open Access
- 20 April 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (5) , 1046-1054
- https://doi.org/10.1002/mrm.20451
Abstract
Contrast‐to‐noise ratio (CNR) in blood oxygenation level‐dependent (BOLD) based functional MRI (fMRI) studies is a fundamental parameter to determine statistical significance and therefore to map functional activation in the brain. The CNR is defined here as BOLD contrast with respect to temporal fluctuation. In this study, a theoretical noise model based on oxygenation‐sensitive MRI signal formation is proposed. No matter what the noise sources may be in the signal acquired by a gradient‐echo echo‐planar imaging pulse sequence, there are only three noise elements: apparent spin density fluctuations,S0(t); transverse relaxation rate fluctuations,R(t); and thermal noise,n(t). The noise contributions fromS0(t),R(t), andn(t) to voxel time course fluctuations were evaluated as a function of echo time (TE) at 3 T. Both noise contributions caused byS0(t) andR(t) are significantly larger than that of thermal noise when TE = 30 ms. In addition, the fluctuations betweenS0(t) andR(t) are cross‐correlated and become a noise factor that is large enough and cannot be ignored. The experimentally measured TE dependences of noise, temporal signal‐to‐noise ratio, and BOLD CNR in finger‐tapping activation regions were consistent with the proposed model. Furthermore, the proposed theoretical models not only unified previously proposed BOLD CNR models, but also provided mechanisms for interpreting apparent controversies and limitations that exist in the literature. Magn Reson Med 53:1046–1054, 2005.Keywords
This publication has 34 references indexed in Scilit:
- EPI‐BOLD fMRI of human motor cortex at 1.5 T and 3.0 T: Sensitivity dependence on echo time and acquisition bandwidthJournal of Magnetic Resonance Imaging, 2003
- T2* Dependence of Low Frequency Functional ConnectivityNeuroImage, 2002
- Physiological noise in oxygenation‐sensitive magnetic resonance imagingMagnetic Resonance in Medicine, 2001
- Localization of Cardiac-Induced Signal Change in fMRINeuroImage, 1999
- Decomposition of inflow and blood oxygen level‐dependent (BOLD) effects with dual‐echo spiral gradient‐recalled echo (GRE) fMRIMagnetic Resonance in Medicine, 1996
- Reduction of physiological fluctuations in fMRI using digital filtersMagnetic Resonance in Medicine, 1996
- Functional connectivity in the motor cortex of resting human brain using echo‐planar mriMagnetic Resonance in Medicine, 1995
- Cerebrospinal fluid flowNeuroradiology, 1992
- The signal-to-noise ratio of the nuclear magnetic resonance experimentJournal of Magnetic Resonance (1969), 1976
- Pulsatile Movements in the CSF PathwaysThe British Journal of Radiology, 1966