Resolution and noise in xeromammography
- 1 November 1982
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 9 (6) , 819-829
- https://doi.org/10.1118/1.595190
Abstract
The resolution and noise characteristics of the xeromammographic image are analyzed by means of a multistage model which considers the exposure, toner deposition, and toner transfer steps. A frequency‐dependent theory of xeromammographic noise is developed and comparison is made with experimental results. Central to this theory is the concept of a toner electrode formed in the immediate vicinity of the Se layer. Comparison is also made between the imaging capabilities of xeromammography and screen/film systems. The paper concludes by addressing the question of normalization of the transfer function in an electrostatic system.Keywords