Evaluation of manual and automatic segmentation of the mouse heart from CINE MR images
Open Access
- 29 November 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (1) , 86-93
- https://doi.org/10.1002/jmri.21236
Abstract
Purpose To compare global functional parameters determined from a stack of cinematographic MR images of mouse heart by a manual segmentation and an automatic segmentation algorithm. Materials and Methods The manual and automatic segmentation results of 22 mouse hearts were compared. The automatic segmentation was based on propagation of a minimum cost algorithm in polar space starting from manually drawn contours in one heart phase. Intra‐ and interobserver variability as well as validity of the automatic segmentation was determined. To test the reproducibility of the algorithm the variability was calculated from the intra‐ and interobserver input. Results The mean time of segmentation for one dataset was around 10 minutes and ≈2.5 hours for automatic and manual segmentation, respectively. There were no significant differences between the automatic and the manual segmentation except for the end systolic epicardial volume. The automatically derived volumes correlated well with the manually derived volumes (R2 = 0.90); left ventricular mass with and without papillary muscle showed a correlation R2 of 0.74 and 0.76, respectively. The manual intraobserver variability was superior to the interobserver variability and the variability of the automatic segmentation, while the manual interobserver variability was comparable to the variability of the automatic segmentation. The automatic segmentation algorithm reduced the bias of the intra‐ and interobserver variability. Conclusion We conclude that automatic segmentation of the mouse heart provides a fast and valid alternative to manual segmentation of the mouse heart. J. Magn. Reson. Imaging 2007.Keywords
This publication has 31 references indexed in Scilit:
- Comparison between prospective and retrospective triggering for mouse cardiac MRINMR in Biomedicine, 2006
- Xanthine oxidase inhibitors improve energetics and function after infarction in failing mouse heartsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2006
- Creatine kinase knockout mice show left ventricular hypertrophy and dilatation, but unaltered remodeling post-myocardial infarctionCardiovascular Research, 2005
- Cine-MRI assessment of cardiac function in mice anesthetized with ketamine/xylazine and isofluraneMagnetic Resonance Materials in Physics, Biology and Medicine, 2004
- Simultaneous assessment of left‐ventricular infarction size, function and tissue viability in a murine model of myocardial infarction by cardiac manganese‐enhanced magnetic resonance imaging (MEMRI)NMR in Biomedicine, 2004
- Dystrophin‐ and MLP‐deficient mouse hearts: marked differences in morphology and function, but similar accumulation of cytoskeletal proteinsThe FASEB Journal, 2004
- Assessment of global and regional myocardial function in the mouse using cine and tagged MRIMagnetic Resonance in Medicine, 2003
- Automated contour detection of the left ventricle in short axis view in 2D echocardiogramsMachine Vision and Applications, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- CIII. The invention of a general method for determining the sum of every 2d, 3d, 4th, or 5th, &c. term of a series, taken in order; the sum of the whole series being knownPhilosophical Transactions of the Royal Society of London, 1757