Revision of a Failed Cemented Total Hip Prosthesis with Insertion of an Acetabular Component without Cement and a Femoral Component with Cement. A Five to Eight-Year Follow-up Study*
- 1 July 1996
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 78 (7) , 982-94
- https://doi.org/10.2106/00004623-199607000-00002
Abstract
Coated Harris-Galante acetabular component inserted without cement and an Iowa femoral component inserted with cement. Contemporary cementing techniques were used, but structural bone graft was not. The over-all prevalence of repeat revision for aseptic loosening was 0 per cent for the acetabular components and 3 per cent (two hips) for the femoral components. In addition, 2 per cent (one) of the acetabular components and 5 per cent (three) of the femoral components demonstrated radiographic evidence of loosening. In the forty-three patients (forty-nine hips) who were alive at an average of seventy-four months (range, sixty to ninety-five months) after the revision, none of the acetabular components and 2 per cent (one) of the femoral components were revised again for aseptic loosening. An additional 2 per cent (one) of the acetabular components and 6 per cent (three) of the femoral components were radiographically loose. Ninety-eight per cent (forty-one) of the forty-two living patients (98 per cent [forty-seven] of the forty-eight hips) who had a clinical examination at least five years after the revision had increased function; 90 per cent (thirty-eight) of these patients (forty-four [92 per cent] of the hips) were satisfied with the result.The group that had a hybrid revision was compared with a group of seventy patients (seventy-four hips) who had had a revision total hip arthroplasty with use of contemporary cementing techniques for both components. These revisions had been performed by the same surgeon, before he performed the hybrid revisions, and the prevalence of repeat revision of the acetabular component was 7 per cent (five hips) and that of the femoral component was 4 per cent (three hips). In addition, 16 per cent (twelve) of the acetabular components and 3 per cent (two) of the femoral components were radiographically loose. The comparison group was not a consecutive series, as only the patients who had had radiographs made five to eight years after the revision were evaluated. In the fifty-two such patients (fifty-six hips) who were alive at five years after the revision with cement (average duration of radiographic follow-up, seventy-seven months; range, sixty to ninety-nine months), 9 per cent (five) of the acetabular components and 5 per cent (three) of the femoral components were revised again for aseptic loosening. An additional 21 per cent (twelve) of the acetabular components and 4 per cent (two) of the femoral components were radiographically loose.The results of the present study demonstrated a significant improvement (p = 0.0001) in the survival of the acetabular component of so-called hybrid revision total hip arthroplasties compared with that of revision total hip arthroplasties with cement performed by the same surgeon and followed for a comparable period....Keywords
This publication has 46 references indexed in Scilit:
- Revision of the acetabulum without cement with use of the Harris-Galante porous-coated implant. Two to eight-year results.Journal of Bone and Joint Surgery, 1994
- Revision total hip arthroplasty with the BIAS (Biologic Ingrowth Anatomic System) femoral component. Three to six-year results.Journal of Bone and Joint Surgery, 1994
- Outcome of revision hip arthroplasty done without cement.Journal of Bone and Joint Surgery, 1994
- The results of improved cementing techniques for total hip arthroplasty in patients less than fifty years old. A ten-year follow-up study.Journal of Bone and Joint Surgery, 1994
- Impacted cancellous allografts and cement for revision total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 1993
- Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic reviewThe Journal of Bone and Joint Surgery. British volume, 1992
- Evaluation of cementless acetabular component migrationThe Journal of Arthroplasty, 1989
- Deep infection in Charnley low-friction arthroplasty. Comparison of plain and gentamicin-loaded cementThe Journal of Bone and Joint Surgery. British volume, 1987
- Revision total hip arthroplasty.Journal of Bone and Joint Surgery, 1985
- Metal/cement interface strength in cemented stem fixationJournal of Orthopaedic Research, 1984