Blood Flow Volume Quantification of Cerebral Ischemia
- 1 March 2002
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 178 (3) , 551-556
- https://doi.org/10.2214/ajr.178.3.1780551
Abstract
OBJECTIVE. Determination of blood flow volume is useful in assessing ischemic cerebrovascular disease. We compared the blood flow volume measurement of three noninvasive imaging techniques, namely color velocity imaging quantification, spectral Doppler imaging quantification, and MR phase-contrast flow quantification, to see how well the flow values determined by each technique agreed with one another. SUBJECTS AND METHODS. Flow volume quantification was tested experimentally using a flow simulator and by the three techniques in the vertebral and internal carotid arteries of 40 patients with histories of cerebral ischemia. In the flow simulation study, the flow values in each technique were compared with the phantom flow by the Wilcoxon's signed rank test. In the patient study, the flow values between each paired technique were compared by paired t test. The significance level was taken at p less than 0.05. RESULTS. Flow volumes were measured by color velocity imaging quantification. MR phase-contrast flow quantification agreed with the phantom flow simulation within the tested range, and spectral Doppler imaging quantification values were significantly overestimated. In patients, a large variation of the blood flow volume was obtained between each technique (p < 0.05). Among them, spectral Doppler imaging quantification showed the highest flow values in the vessels (internal carotid arteries, 312.6 mL/min; vertebral arteries, 112.0 mL/min), followed by color velocity imaging quantification (internal carotid arteries, 216.8 mL/min; vertebral arteries, 58.1 mL/min) and MR phase-contrast flow quantification (internal carotid arteries, 169.1 mL/min; vertebral arteries, 66.5 mL/min). CONCLUSION. Blood flow volume measurements determined by the three noninvasive imaging techniques on the same vessel can differ widely, and spectral Doppler imaging quantification consistently overestimated the flow volume. It is, therefore, essential that the same technique, preferably color velocity imaging quantification or MR phase-contrast flow quantification, be used for clinical follow-up investigations in the future.Keywords
This publication has 11 references indexed in Scilit:
- Preferred technique for blood flow volume measurement in cerebrovascular disease.Stroke, 2000
- Reference Values for Vertebral Artery Flow Volume by Duplex Sonography in Young and Elderly AdultsStroke, 1999
- Vasodilatory Responses and Magnetic Resonance AngiographyJournal of Neuroimaging, 1997
- Clinical Cerebrovascular Applications of Arterial Ultrasound Volume Flow Rate EstimatesJournal of Neuroimaging, 1996
- Accuracy of duplex scanning for measurement of arterial volume flowJournal of Vascular Surgery, 1992
- Correlation of common carotid flow volume measured by ultrasonic quantitative flowmeter with pathological findings.Stroke, 1991
- Quantitative common carotid artery blood flow: Prediction of internal carotid artery stenosisJournal of Vascular Surgery, 1986
- Time Domain Formulation of Pulse-Doppler Ultrasound and Blood Velocity Estimation by Cross CorrelationUltrasonic Imaging, 1986
- Measurement of blood flow by ultrasound: Accuracy and sources of errorUltrasound in Medicine & Biology, 1985
- Measurement of carotid blood flow in man and its clinical application.Stroke, 1983