Anatomical dead space, ventilatory pattern, and exercise capacity in chronic heart failure.
Open Access
- 1 October 1995
- Vol. 74 (4) , 377-380
- https://doi.org/10.1136/hrt.74.4.377
Abstract
BACKGROUND--Patients with chronic heart failure have an excessive ventilatory response to exercise, characterised by an increase in the slope of the relation between ventilation and carbon dioxide production (VE/VCO2 slope). Patients have an altered respiratory pattern with an increased respiratory rate (f) at a given tidal volume (VT), which may result in increased anatomical dead space ventilation. METHODS--The ventilatory responses in 88 patients with chronic heart failure and 43 age matched controls during maximal incremental treadmill exercise were analysed. Peak oxygen consumption (VO2), VE/VCO2 slope, and the slope of the relation between f and VT were derived. Anatomical dead space was estimated from a standard formula and anatomical dead space ventilation calculated. RESULTS--Peak VO2 was greater (mean (SD)) (33.2 (8.5) v 19.4 (6.7) ml/min/kg; P < 0.001) and the VE/VCO2 slope lower in the controls (25.96 (4.16) v 35.14 (9.80); P < 0.001). During matched submaximal exercise VT was higher (1.97 (0.92) v 1.68 (0.62) 1; P < 0.05) and flower in the controls (18.23 (6.48) v 24.28 (7.58); P < 0.001). At peak exercise there was no difference in f, but VT was higher in the controls (2.66 (0.97) v 1.90 (0.61) 1; P < 0.001). The VT/f slope was the same (0.04 (0.04)) in both groups. The intercept of the relation was greater for the control group (1.31 (1.28) v 0.59 (0.83); P < 0.001). Anatomical dead space ventilation was lower in the controls at submaximal work load (4.17 (1.56) v 5.58 (1.93) l/min; P < 0.001). At peak exercise anatomical dead space ventilation was the same in both groups, but was lower expressed as a percentage of total VE in the control group (9.8 (3.3) v 13.5 (4.0); P < 0.001). There were weak relations within the heart failure group alone between VT/f slope and peak VO2 and VE/VCO2 slope. CONCLUSIONS--The relation between anatomical dead space ventilation and VE/VCO2 slope is expected: as f increases, so do VE/VCO2 slope and anatomical dead space ventilation. The VT/f slope was the same in patients with chronic heart failure and controls, so change in respiratory pattern cannot explain the increase in VE/VCO2 slope. The stimulus causing the increased f has yet to be identified.Keywords
This publication has 14 references indexed in Scilit:
- Usefulness of arterial blood gas estimations during exercise in patients with chronic heart failure.Heart, 1994
- Relationship between ventilation and carbon dioxide production in normal subjects with induced changes in anatomical dead spaceEuropean Journal of Clinical Investigation, 1993
- Exercise hyperventilation chronic congestive heart failure, and its relation to functional capacity and hemodynamicsThe American Journal of Cardiology, 1992
- Ventilatory mechanisms of exercise intolerance in chronic heart failureAmerican Heart Journal, 1992
- A critical threshold of exercise capacity in the ventilatory response to exercise in heart failure.Heart, 1991
- Mechanism of the increased ventilatory response to exercise in patients with chronic heart failure.Heart, 1990
- Increased exercise ventilation in patients with chronic heart failure: intact ventilatory control despite hemodynamic and pulmonary abnormalities.Circulation, 1988
- Arterial oxygenation and arterial oxygen transport in chronic myocardial failure at rest, during exercise and after hydralazine treatment.Circulation, 1982
- Oxygen utilization and ventilation during exercise in patients with chronic cardiac failure.Circulation, 1982
- The measurement of metabolic gas exchange and minute volume by mass spectrometry aloneRespiration Physiology, 1979