On compensator design for photon beam intensity-modulated conformal therapy
- 1 May 1998
- journal article
- Published by Wiley in Medical Physics
- Vol. 25 (5) , 668-675
- https://doi.org/10.1118/1.598250
Abstract
Recently the compensator has been shown to be an in expensive and reliable dose delivery device for photon beam intensity-modulated radiation therapy (IMRT). The goal of IMRT compensator design is to produce an optimized primary fluence profile at the patient's surface obtained from the optimization procedure. In this paper some of the problems associated with IMRT compensator design, specifically the beam perturbations caused by the compensator, are discussed. A simple formula is derived to calculate the optimal compensator thickness profile from an optimized primary fluence profile. The change of characteristics of a 6 MV beam caused by the introduction of cerrobend compensators in the beam is investigated using OMEGA Monte Carlo codes. It is found that the compensator significantly changes the energy spectrum and the mean energy of the primary photons at the patient's surface. However, beam hardening does not have as significant an effect on the percent depth dose as it does on the energy spectrum. We conclude that in most situations the beam hardening effect can be ignored during compensator design and dose calculation. The influence of the compensator on the contaminant electron buildup dose is found to be small and independent of the compensator thickness of interest. Therefore, it can be ignored in the compensator design and included as a correction into the final dose distribution. The scattered photons from the compensator are found to have no effect on the surface dose. These photons produce a uniform low fluence distribution at the patient's surface, which is independent of compensator shape. This is also true for very large fields and extremely asymmetric and nonuniform compensator thickness profiles. Compared to the primary photons, the scattered photons have much larger angular spread and similar energy spectrum at the patient's surface. These characteristics allow the compensator thickness profile and the dose distribution to be calculated from the optimized fluence profile of primary photons, without considering the scattered photons.Keywords
This publication has 10 references indexed in Scilit:
- Number and orientations of beams in intensity‐modulated radiation treatmentsMedical Physics, 1997
- Simultaneous optimization of dynamic multileaf collimation and scanning patterns or compensation filters using a generalized pencil beam algorithmMedical Physics, 1995
- BEAM: A Monte Carlo code to simulate radiotherapy treatment unitsMedical Physics, 1995
- Optimization of the dose delivery in a few field techniques using radiobiological objective functionsMedical Physics, 1993
- A standard timing benchmark for EGS4 Monte Carlo calculationsMedical Physics, 1992
- 3‐D dose‐volume compensation using nonlinear least‐squares regression techniqueMedical Physics, 1991
- Optimal design of radiation compensatorsMedical Physics, 1990
- An algorithm for design of beam compensatorsInternational Journal of Radiation Oncology*Biology*Physics, 1989
- The field integrated dose modification (FIDM): Three typical clinical applications of a new irradiation techniqueRadiotherapy and Oncology, 1988
- Improving the buildup and depth‐dose characteristics of high energy photon beams by using electron filtersMedical Physics, 1979