MAX meets ADAM: a dosimetric comparison between a voxel-based and a mathematical model for external exposure to photons
- 24 February 2004
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (6) , 887-910
- https://doi.org/10.1088/0031-9155/49/6/002
Abstract
The International Commission on Radiological Protection intends to revise the organ and tissue equivalent dose conversion coefficients published in various reports. For this purpose the mathematical human medical internal radiation dose (MIRD) phantoms, actually in use, have to be replaced by recently developed voxel-based phantoms. This study investigates the dosimetric consequences, especially with respect to the effective male dose, if not only a MIRD phantom is replaced by a voxel phantom, but also if the tissue compositions and the radiation transport codes are changed. This task will be resolved by systematically replacing in the mathematical ADAM/GSF exposure model, first the radiation transport code, then the tissue composition and finally the phantom anatomy, in order to arrive at the voxel-based MAX/EGS4 exposure model. The results show that the combined effect of these replacements can decrease the effective male dose by up to 25% for external exposures to photons for incident energies above 30 keV for different field geometries, mainly because of increased shielding by a heterogeneous skeleton and by the overlying adipose and muscle tissue, and also because of the positions internal organs have in a realistically designed human body compared to their positions in the mathematically constructed phantom.Keywords
This publication has 23 references indexed in Scilit:
- All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetryPhysics in Medicine & Biology, 2003
- ORGAN DOSE CONVERSION COEFFICIENTS FOR 0.1–10 MeV ELECTRONS CALCULATED FOR THE VIP-MAN TOMOGRAPHIC MODELHealth Physics, 2001
- CONVERSION COEFFICIENTS BASED ON THE VIP-MAN ANATOMICAL MODEL AND EGS4-VLSI CODE FOR EXTERNAL MONOENERGETIC PHOTONS FROM 10 keV TO 10 MeVHealth Physics, 2001
- Voxel Anthropomorphic Models as a Tool for Internal DosimetryRadiation Protection Dosimetry, 1998
- A Realistic Anthrompomorphic Phantom for Calculating Specific Absorbed Fractions of Energy Deposited from Internal Gamma EmittersRadiation Protection Dosimetry, 1998
- A Realistic Anthropomorphic Phantom for Calculating Organ Doses Arising from External Photon IrradiationRadiation Protection Dosimetry, 1997
- PENELOPE: An algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matterNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1995
- Specific absorbed fractions of energy at various ages from internal photon sources: 1, MethodsPublished by Office of Scientific and Technical Information (OSTI) ,1987
- Photoelectron Enhancement of the Absorbed Dose from X Rays to Human Bone Marrow: Experimental and Theoretical StudiesThe British Journal of Radiology, 1985
- Relativistic atomic form factors and photon coherent scattering cross sectionsJournal of Physical and Chemical Reference Data, 1979