Purification and preconcentration of genomic DNA from whole cell lysates using photoactivated polycarbonate (PPC) microfluidic chips
Open Access
- 31 May 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 34 (10) , e74
- https://doi.org/10.1093/nar/gkl146
Abstract
We discuss the use of a photoactivated polycarbonate (PPC) microfluidic chip for the solid-phase, reversible immobilization (SPRI) and purification of genomic DNA (gDNA) from whole cell lysates. The surface of polycarbonate was activated by UV radiation resulting in a photo-oxidation reaction, which produced a channel surface containing carboxylate groups. The gDNA was selectively captured on this photoactivated surface in an immobilization buffer, which consisted of 3% polyethylene glycol, 0.4 M NaCl and 70% ethanol. The methodology reported herein is similar to conventional SPRI in that surface-confined carboxylate groups are used for the selective immobilization of DNA; however, no magnetic beads or a magnetic field are required. As observed by UV spectroscopy, a load of approximately 7.6 +/- 1.6 microg/ml of gDNA was immobilized onto the PPC bed. The recovery of DNA following purification was estimated to be 85 +/- 5%. The immobilization and purification assay using this PPC microchip could be performed within approximately 25 min as follows: (i) DNA immobilization approximately 6 min, (ii) chip washout with ethanol 10 min, and (iii) drying and gDNA desorption approximately 6 min. The PPC microchip could also be used for subsequent assays with no substantial loss in recovery, no observable carryover and no need for 'reactivation' of the PC surface with UV light.Keywords
This publication has 19 references indexed in Scilit:
- Resist-Free Patterning of Surface Architectures in Polymer-Based Microanalytical DevicesJournal of the American Chemical Society, 2004
- Microchip-Based Purification of DNA from Biological SamplesAnalytical Chemistry, 2003
- Surface modification and characterization of microfabricated poly(carbonate) devices: manipulation of electroosmotic flowThe Analyst, 2002
- Microfluidic devices fabricated in poly(methyl methacrylate) using hot-embossing with integrated sampling capillary and fiber optics for fluorescence detectionLab on a Chip, 2002
- High-Throughput Plasmid Purification for Capillary SequencingGenome Research, 2001
- Laser Modification of Preformed Polymer Microchannels: Application To Reduce Band Broadening around Turns Subject to Electrokinetic FlowAnalytical Chemistry, 2001
- Evaluation of Silica Resins for Direct and Efficient Extraction of DNA from Complex Biological Matrices in a Miniaturized FormatAnalytical Biochemistry, 2000
- Rapid, Automated Nucleic Acid Probe Assays Using Silicon Microstructures for Nucleic Acid ConcentrationJournal of Biomechanical Engineering, 1999
- A universal protocol for PCR detection of 13 species of foodborne pathogens in foodsJournal of Applied Microbiology, 1997
- [42] Fractionation of DNA fragments by polyethylene glycol induced precipitationPublished by Elsevier ,1980