Regular Monitoring of Access Flow Compared with Monitoring of Venous Pressure Fails to Improve Graft Survival
- 1 October 2003
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of the American Society of Nephrology
- Vol. 14 (10) , 2645-2653
- https://doi.org/10.1097/01.asn.0000089562.98338.60
Abstract
Regular vascular access blood flow (Qa) surveillance is recommended to detect graft stenosis; however, there is little evidence that monitoring and correcting with angioplasty improves graft survival. This blinded, randomized, controlled trial of 112 patients studied time to graft thrombosis and graft loss, comparing monthly Qa plus standard surveillance (dynamic venous pressure and physical examination) (treatment group) to standard surveillance alone (control group). Only the treatment group was referred for angiogram if Qa 50%. The rate of graft thrombosis per patient-year at risk was 0.41 and 0.51 in the control and treatment groups, respectively. Fifty-one interventions (0.93/patient-years at risk) were performed in the treatment group versus 31 interventions (0.61/patient-years at risk) in the control group. There was no difference in time to graft loss (P = 0.890). In a multivariate analysis, aspirin (ASA) therapy at baseline was associated with an 84% reduction in risk of graft thrombosis (odds ratio [OR], 0.14; P = 0.002). Higher baseline Qa (OR, 0.84; P = 0.05) and longer interval since graft insertion (OR, 0.97; P = 0.07) were associated with a decrease in graft thrombosis. Results reveal that graft surveillance that uses Qa increases the detection of stenosis, compared with standard surveillance; however, intervention with angioplasty does not improve the time to graft thrombosis or time to graft loss. E-mail: louise.moist@lhsc.on.caKeywords
This publication has 13 references indexed in Scilit:
- Development of a Method for Measuring Hemodialysis Access Flow: From Idea to Robust TechnologySeminars in Dialysis, 2007
- Value of static venous pressure for predicting arteriovenous graft thrombosisKidney International, 2002
- Vascular access blood flow monitoring reduces access morbidity and costsKidney International, 2001
- Clinical performance characteristics of hemodialysis graft monitoringKidney International, 2001
- Flow in hemodialysis grafts after angioplasty: Do radiologic criteria predict success?Kidney International, 2001
- Graft surveillance: Venous pressure, access flow, or the combination?Kidney International, 2001
- Hemodialysis arteriovenous access: Detection of stenosis and response to treatment by vascular access blood flowKidney International, 2001
- Vascular access for hemodialysisKidney International, 1999
- A comparison between PTFE and denatured homologous vein grafts for haemodialysis access: a prospective randomised multicentre trialEuropean Journal of Vascular and Endovascular Surgery, 1998
- Predicting Survival in Patients with Early Alzheimer’s DiseaseDementia and Geriatric Cognitive Disorders, 1998