Cochlear Implant Melody Recognition as a Function of Melody Frequency Range, Harmonicity, and Number of Electrodes
- 1 April 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 30 (2) , 160-168
- https://doi.org/10.1097/aud.0b013e31819342b9
Abstract
Objective: The primary goal of the present study was to determine how cochlear implant melody recognition was affected by the frequency range of the melodies, the harmonicity of these melodies, and the number of activated electrodes. The secondary goal was to investigate whether melody recognition and speech recognition were differentially affected by the limitations imposed by cochlear implant processing. Design: Four experiments were conducted. In the first experiment, 11 cochlear implant users used their clinical processors to recognize melodies of complex harmonic tones with their fundamental frequencies being in the low (104–262 Hz), middle (207–523 Hz), and high (414–1046 Hz) ranges. In the second experiment, melody recognition with pure tones was compared to melody recognition with complex harmonic tones in four subjects. In the third experiment, melody recognition was measured as a function of the number of electrodes in five subjects. In the fourth experiment, vowel and consonant recognition were measured as a function of the number of electrodes in the same five subjects who participated in the third experiment. Results: Frequency range significantly affected cochlear implant melody recognition, with higher frequency ranges producing better performance. Pure tones produced significantly better performance than complex harmonic tones. Increasing the number of activated electrodes did not affect performance with low- and middle-frequency melodies but produced better performance with high-frequency melodies. Large individual variability was observed for melody recognition, but its source seemed to be different from the source of the large variability observed in speech recognition. Conclusion: Contemporary cochlear implants do not adequately encode either temporal pitch or place pitch cues. Melody recognition and speech recognition require different signal processing strategies in future cochlear implants.Keywords
This publication has 51 references indexed in Scilit:
- Fundamental frequency discrimination and speech perception in noise in cochlear implant simulationsHearing Research, 2007
- Spectral and Temporal Cues in Cochlear Implant Speech PerceptionEar & Hearing, 2006
- Acoustic to Electric Pitch Comparisons in Cochlear Implant Subjects with Residual HearingJournal of the Association for Research in Otolaryngology, 2006
- Improved Music Perception with Explicit Pitch Coding in Cochlear ImplantsAudiology and Neurotology, 2006
- Speech Understanding in Noise with a Med-El COMBI 40+ Cochlear Implant Using Reduced Channel SetsEar & Hearing, 2002
- Speech Perception as a Function of Electrical Stimulation Rate: Using the Nucleus 24 Cochlear Implant SystemEar & Hearing, 2000
- A new portable sound processor for the University of Melbourne/Nucleus Limited multielectrode cochlear implantThe Journal of the Acoustical Society of America, 1992
- A cochlear frequency-position function for several species—29 years laterThe Journal of the Acoustical Society of America, 1990
- Pitch perception by cochlear implant subjectsThe Journal of the Acoustical Society of America, 1987
- Frequencies Dominant in the Perception of the Pitch of Complex SoundsThe Journal of the Acoustical Society of America, 1967