Comparison of the Strength and Holding Power of 4 Pin Designs for Use with Half Pin (Type I) External Skeletal Fixation
- 1 May 1987
- journal article
- research article
- Published by Wiley in Veterinary Surgery
- Vol. 16 (3) , 207-211
- https://doi.org/10.1111/j.1532-950x.1987.tb00940.x
Abstract
The strength and holding power of four pin designs for use with half pin (type I) external skeletal fixation were evaluated. Pins that were tested were fully threaded, nonthreaded, two cortices partially threaded, and one cortex partially threaded. The study involved three parts: (1) resistance of the pins to axial extraction immediately after insertion; (2) resistance of the pins to axial extraction 8 weeks after being inserted into the tibiae of live dogs; and (3) resistance of the pins to bending load. Pins with threads engaging two cortices were more resistant to axial extraction than nonthreaded pins in both the acute (p < 0.0001) and chronic (p < 0.0001) studies. Nonthreaded pins were more resistant to bending than fully threaded and two cortices partially threaded pins (p < 0.0005). One cortex partially threaded pins possessed similar bending strength to nonthreaded pins (p = 0.21) and had 5.3 times more resistance to axial extraction in the acute study (p < 0.0001) and 6.9 times more in the chronic study (p < 0.0001). Though one cortex partially threaded pins were not as resistant to axial extraction as pins with threads engaging two cortices (p < 0.0001), they were more resistant to bending loads (p < 0.0005). Loss of bolding power and pin failure are two of the most serious problems associated with fracture stabilization using external skeletal fixation. The results of this study suggest that one cortex partially threaded pins are better at maintaining holding power and resisting bending and breaking than nonthreaded pins. With some compromise in holding power, they are also better at resisting failure than pins with threads engaging two cortices.This publication has 6 references indexed in Scilit:
- Effect of Fixation Pin Insertion on the Bone‐Pin InterfaceVeterinary Surgery, 1986
- Static Strength Evaluation of Six External Skeletal Fixation ConfigurationsVeterinary Surgery, 1983
- An In Vitro Comparison of the Holding Strength of Partially Threaded vs Nonthreaded Intramedullary PinsVeterinary Surgery, 1983
- The mechanical performance of the standard Hoffmann-Vidal external fixation apparatus.Journal of Bone and Joint Surgery, 1982
- Principles and Application of External Skeletal FixationVeterinary Clinics of North America, 1975