pH-Mediated field-amplified sample stacking of pharmaceutical cations in high-ionic strength samples
- 17 January 2001
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 22 (1) , 59-65
- https://doi.org/10.1002/1522-2683(200101)22:1<59::aid-elps59>3.0.co;2-u
Abstract
Capillary electrophoretic separation of samples of physiological origin typically have both poor resolution and efficiency due to destacking. We have previously reported a stacking method for concentration of catecholamines in artifical dialysate, or Ringer's solution. However, pH‐mediated sample stacking of other cations has not been investigated. In this report, pH‐mediated stacking has been extended to eletripan, dofetilide, doxazosin, sildenafil, UK‐103,320, UK‐202,581, and CP‐122,288. These compounds were chosen without prior structural screening except that they were cationic at the pH of our background electrolyte (BGE). Capillary electrophoretic behavior of samples in BGE is compared with those of samples in Ringer's solution with and without pH‐mediated acid stacking. Results indicate that the peak heights and efficiencies for acid‐stacked samples are increased compared to the unstacked samples in Ringer's solution or BGE. For example, the peak efficiencies for 5 s injections of eletriptan in BGE and Ringer's solution are 138000 and 72000 plates, respectively. In contrast, a 10 s injection of eletriptan followed by acid injection for 16 s produces a peak with 246000 plates. Evaluation of the stacking effect was performed by comparison of the peak height at similar peak efficiencies for samples in Ringer's solution with and without stacking. Using this method, pH‐mediated acid stacking provides a 10‐ to 27‐fold sensitivity enhancement for the seven cations.Keywords
This publication has 24 references indexed in Scilit:
- Ion exchange-based preconcentration for the determination of anions by capillary electrophoresisJournal of Chromatography A, 2000
- Large volume sample stacking of positively chargeable analytes in capillary zone electrophoresis without polarity switching: Use of low reversed electroosmotic flow induced by a cationic surfactant at acidic pHElectrophoresis, 2000
- On-line ion-exchange preconcentration in a flow injection system coupled to capillary electrophoresis for the direct determination of UV absorbing anionsAnalytica Chimica Acta, 1999
- Capillary zone electrophoresis separations of enantiomers present in complex ionic matrices with on-line isotachophoretic sample pretreatmentJournal of Chromatography A, 1999
- At-line solid-phase extraction for capillary electrophoresis: application to negatively charged solutesJournal of Chromatography B: Biomedical Sciences and Applications, 1998
- Identification of proteins by capillary electrophoresis-tandem mass spectrometry evaluation of an on-line solid-phase extraction deviceJournal of Chromatography A, 1997
- Preconcentration and microreaction technology on-line with capillary electrophoresisJournal of Chromatography A, 1996
- Sensitivity Enhancement for Capillary ElectrophoresisAnalytical Chemistry, 1993
- Switching valve with internal micro precolumn for on-line sample enrichment in capillary zone electrophoresisJournal of Chromatography A, 1992
- On-Column Sample Concentration Using Field Amplification in CZEAnalytical Chemistry, 1992