Long-term performance of a hand held spirometer.
Open Access
- 1 October 1996
- Vol. 51 (10) , 973-976
- https://doi.org/10.1136/thx.51.10.973
Abstract
BACKGROUND: A study was undertaken to test the long term performance of a small hand held spirometer for self-administered serial spirometric testing. METHODS: Thirty turbine pocket spirometers (MicroMedical DiaryCard) were used in a clinical trial on 22 emphysematous patients with severe alpha 1-antitrypsin deficiency. The spirometers were able to store the date, time, forced expiratory volume in one second (FEV1), forced vital capacity (FVC), peak expiratory flow (PEF), and flow-volume loop for each blow. Every four weeks when the patients came for alpha 1-antitrypsin infusions the performance of their spirometer was checked before and after retrieval of the data from the spirometer. Calibration checks were threefold and included volume calibration with a 1.0 litre and 3.0 litre syringe, and flow calibration with a decompression calibrator. RESULTS: After two years of study the mean number of spirometric recordings performed per spirometer was 693 (range 237-1178), and the mean number of calibration checks was 33 (range 2-57). The coefficient of variation of the calibration signal was 1-2% for syringes and 0.5-1% for the decompression calibrator. The bearings of one turbine exhibited excessive friction after 17 months. None of the other 29 instruments showed drift, and a general drift of all spirometers towards larger or smaller readings could not be shown. However, unforeseen problems in the stability of the calibrating devices were observed. CONCLUSIONS: The small hand held turbine spirometers are suitable for long term patient-administered serial spirometric testing. The two year durability is acceptable and the long term reproducibility excellent.Keywords
This publication has 7 references indexed in Scilit:
- Patient-administered sequential spirometry in healthy volunteers and patients with α1-antitrypsin deficiencyRespiratory Medicine, 1996
- Do asthmatic patients correctly record home spirometry measurements?BMJ, 1994
- Daily home spirometry facilitates early detection of rejection in single lung transplant recipients with emphysemaEuropean Respiratory Journal, 1993
- The Use of Home Spirometry in Detecting Acute Lung Rejection and Infection Following Heart-Lung TransplantationChest, 1990
- A device for evaluation of flow recording equipment.1983
- A clinical trial of efficacy of antiproteolytic therapy: can it be done?Published by Elsevier ,1983
- Pocket-sized device for measuring forced expiratory volume in one second and forced vital capacity.BMJ, 1982