Intravascular Extraction of Chronic Pacemaker Leads: Efficacy and Follow‐Up
- 1 December 1993
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 16 (12) , 2333-2336
- https://doi.org/10.1111/j.1540-8159.1993.tb02346.x
Abstract
Extraction of chronic pacemaker leads has been recommended for infections, prevention of venous thrombosis, migration, and possible perforation. Success with constant traction techniques has been variable, and the cost and morbidity of open chest surgical procedures are prohibitive. Efficacy of a new system for lead extraction using intravascular techniques was analyzed. The system (Cook Pacemaker) uses a locking stylet, which is secured at the distal electrode by counterclockwise rotation to reinforce the lead and facilitate traction, and dilator sheaths that are used to free the lead from adhesions in the venous system. In a series of 56 patients (ages 19–88)who presented for lead extraction because of erosion (5), infection (14), lead replacement (35), or other (2), 86 leads were extracted. Thirty-two were atrial leads and 54 ventricular; 23 had active fixation and 63 passive. Average duration of implant was 58 ±42 months (range 1–264). Eighty-four leads were totally removed and two partially removed. For these two leads, the distal tip was not removed; in both cases the locking stylet was not secured at the distal electrode due to obstruction within the lead. Two patients developed arm edema following the procedure, which resolved with elevation. One patient developed a subclavian thrombosis, which resolved with warfarin anticoagulation. Four patients have expired due to unrelated causes. In conclusion, this intravascular approach for extraction of chronic leads is effective, and the procedure is safe when performed by experienced personnel.Keywords
This publication has 17 references indexed in Scilit:
- Intravascular Lead Extraction Using Locking Stylets and SheathsPacing and Clinical Electrophysiology, 1990
- Intravascular Lead Extraction Using Locking Stylets, Sheaths, and Other TechniquesPacing and Clinical Electrophysiology, 1990
- Chronic transvenous pacemaker lead removal using a unique, sequential transvenous systemThe American Journal of Cardiology, 1990
- Late Purulent Pacemaker Pocket Infection Caused by Staphylococcus Epidermidis: Serious Complications of In Situ ManagementPacing and Clinical Electrophysiology, 1985
- Functionless retained pacing leads in the cardiovascular system. A complication of pacemaker treatment.Heart, 1985
- Difficulty of extraction of chronically implanted tined ventricular endocardial leadsJournal of the American College of Cardiology, 1984
- Permanent pacemaker infections: Characterization and managementThe American Journal of Cardiology, 1981
- Major venous thrombosis: a complication of transvenous pacemaker electrodes.Heart, 1980
- Complications with retained transvenous pacemaker electrodesAmerican Heart Journal, 1979
- Infection of pacemaker electrode and removal with cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1974