Integrated optical sensing of dissolved oxygen in microtiter plates: A novel tool for microbial cultivation
- 16 January 2003
- journal article
- research article
- Published by Wiley in Biotechnology & Bioengineering
- Vol. 81 (7) , 829-836
- https://doi.org/10.1002/bit.10534
Abstract
Microtiter plates with integrated optical sensing of dissolved oxygen were developed by immobilization of two fluorophores at the bottom of 96‐well polystyrene microtiter plates. The oxygen‐sensitive fluorophore responded to dissolved oxygen concentration, whereas the oxygen‐insensitive one served as an internal reference. The sensor measured dissolved oxygen accurately in optically well‐defined media. Oxygen transfer coefficients, kLa, were determined by a dynamic method in a commercial microtiter plate reader with an integrated shaker. For this purpose, the dissolved oxygen was initially depleted by the addition of sodium dithionite and, by oxygen transfer from air, it increased again after complete oxidation of dithionite. kLa values in one commercial reader were about 10 to 40 h−1. kLa values were inversely proportional to the filling volume and increased with increasing shaking intensity. Dissolved oxygen was monitored during cultivation of Corynebacterium glutamicum in another reader that allowed much higher shaking intensity. Growth rates determined from optical density measurement were identical to those observed in shaking flasks and in a stirred fermentor. Oxygen uptake rates measured in the stirred fermentor and dissolved oxygen concentrations measured during cultivation in the microtiter plate were used to estimate kLa values in a 96‐well microtiter plate. The resulting values were about 130 h−1, which is in the lower range of typical stirred fermentors. The resulting maximum oxygen transfer rate was 26 mM h−1. Simulations showed that the errors caused by the intermittent measurement method were insignificant under the prevailing conditions. © 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 81: 829–836, 2003.Keywords
This publication has 17 references indexed in Scilit:
- Optical method for the determination of the oxygen‐transfer capacity of small bioreactors based on sulfite oxidationBiotechnology & Bioengineering, 2001
- Optical sensor for seawater salinityAnalytical and Bioanalytical Chemistry, 2000
- Methods for Intense Aeration, Growth, Storage, and Replication of Bacterial Strains in Microtiter PlatesApplied and Environmental Microbiology, 2000
- Chemical Engineering DynamicsPublished by Wiley ,2000
- Shake Flask to Fermentor: What Have We Learned?Biotechnology Progress, 1998
- On‐line gas analysis in animal cell cultivation: II. Methods for oxygen uptake rate estimation and its application to controlled feeding of glutamineBiotechnology & Bioengineering, 1995
- Phase fluorometric sterilizable optical oxygen sensorBiotechnology & Bioengineering, 1994
- Bioreactor Scale‐Up for the Oxygen‐Sensitive Culture Bacillus subtilis: The Influence of Stirrer Shaft GeometryBiotechnology Progress, 1992
- Suitability of the shaking flask for oxygen supply to microbiological culturesBioprocess and Biosystems Engineering, 1991
- Determination of oxygen concentrations by luminescence quenching of a polymer-immobilized transition-metal complexAnalytical Chemistry, 1987