Validation of continuous-wave Doppler echocardiographic measurements of mitral and tricuspid prosthetic valve gradients: a simultaneous Doppler-catheter study.
- 1 October 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 74 (4) , 786-795
- https://doi.org/10.1161/01.cir.74.4.786
Abstract
For patients with stenotic native valves, the modified Bernoulli equation (delta P = 4V2) may be applied to Doppler-measured transvalvular velocities to yield an accurate estimate of transvalvular gradients. Although it would be useful if the same approach could be used for those with stenotic prosthetic valves, no previous study has validated the Doppler technique in this setting. We therefore recorded simultaneous continuous-wave Doppler flow profiles and transvalvular manometric gradients in 12 catheterized patients in whom all atrial and ventricular pressures were directly measured (transseptal left atrial catheterization and transthoracic ventricular puncture were performed where necessary). A total of 13 prostheses were studied: 11 mitral (seven porcine, three Starr-Edwards, and one Björk-Shiley) and two tricuspid (one porcine and one Björk-Shiley). The Doppler-determined mean gradient was calculated as the mean of the instantaneous gradients (delta P = 4V2) at 10 msec intervals throughout diastole. The correlation of simultaneous Doppler (DMG) and manometric mean gradients (MG) for the whole group (n = 13) demonstrated a highly significant relationship (MG = 1.07 DMG + 0.28; r = .96, p = .0001). The correlation was equally good for porcine valves alone (n = 8) (MG = 1.06 DMG + 0.55; r = .96, p = .001) and for mechanical valves alone (n = 5) (MG = 1.06 DMG - 0.04; r = .93, p = .02). In a subset of patients without regurgitation (n = 8), prosthetic valve areas were estimated by two Doppler methods originally described by Holen and Hatle, as well as by the invasive Gorlin method. As expected from theoretical considerations, a close correlation was not demonstrated between results of the Gorlin method and those of either Hatle's Doppler method (r = .65, fp = NS) or Holen's method (r = .14, p = NS). Comparison of the results of the two Doppler methods yielded a somewhat closer correlation (r = .73, p less than or equal to .05). These results suggest that in patients with disk-occluder, ball-occluder, and porcine prosthetic valves, Doppler estimates of transvalvular gradients are virtually identical to those obtained invasively.This publication has 25 references indexed in Scilit:
- Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and Bioprosthetic (Hancock and Carpentier-Edwards) cardiac valvesThe American Journal of Cardiology, 1985
- Underestimation of prosthetic mitral valve areas: Role of transseptal catheterization in avoiding unnecessary repeat mitral valve surgeryJournal of the American College of Cardiology, 1985
- Bileaflet, tilting disc and porcine aortic valve substitutes: In vitro hydrodynamic characteristicsJournal of the American College of Cardiology, 1984
- Two-dimensional echocardiographic assessment of complications involving the ionescu-shiley pericardial valve in the mitral positionJournal of the American College of Cardiology, 1984
- Detection of deterioration or infection of homograft and porcine xenograft bioprosthetic valves in mitral and aortic positions by two-dimensional echocardiographic examinationJournal of the American College of Cardiology, 1983
- Determination of pressure gradient in the Hancock mitral valve from noninvasive ultrasound Doppler dataScandinavian Journal of Clinical and Laboratory Investigation, 1981
- Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound.Heart, 1978
- Obstructive Characteristics of Björk‐Shiley, Hancock, and Lillehei‐Kaster Prosthetic Mitral Valves in the Immediate Postoperative PeriodActa Medica Scandinavica, 1978
- Evaluation of Obstructive Characteristics of Mitral Disc Valve Implants with Ultrasound Doppler TechniquesActa Medica Scandinavica, 1977
- Determination of Pressure Gradient in Mitral Stenosis with a Non‐invasive Ultrasound Doppler TechniqueActa Medica Scandinavica, 1976