Noninvasive and Minimally Invasive Methods for Transdermal Glucose Monitoring
- 1 February 2005
- journal article
- research article
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 7 (1) , 174-197
- https://doi.org/10.1089/dia.2005.7.174
Abstract
Noninvasive and minimally invasive techniques for monitoring glucose via the skin are reviewed. These approaches rely either on the interaction of electromagnetic radiation with the tissue or on the extraction of fluid across the barrier. The structure and physiology of the skin make the technical realization of transdermal glucose monitoring a difficult challenge. The techniques involving transdermal fluid extraction circumvent and/or compromise the barrier function of skin's outermost and least permeable layer, the stratum corneum, by the application of physical energy. While sonophoresis and microporation methods, for example, are in relatively early-stage development, a device using reverse iontophoresis [the GlucoWatch Biographer (Cygnus, Inc., Redwood City, CA)] is already commercially available. Optical techniques to monitor glucose are truly noninvasive. The tissue is irradiated, the absorbed or scattered radiation is analyzed, and the information is processed, to provide a measure proportional to the concentration of glucose in the dermal tissue. These techniques include near-infrared and Raman spectroscopy, polarimetry, light scattering, and photoacoustic spectroscopy. By contrast, impedance spectroscopy measures changes in the dielectric properties of the tissue induced by blood glucose variation. Large-scale studies in support of efficacy of these methodologies are as yet unavailable. At present, therefore, transdermal fluid extraction technologies are offering greater promise in terms of practical and realizable devices for patient use. The truly noninvasive allure of the optical approach assures continued and intense research activity--for the moment, however, an affordable, efficient, and portable system is not on the immediate horizon.Keywords
This publication has 128 references indexed in Scilit:
- Temperature-Insensitive Measurement of Glucose Concentration Based on Near Infrared Spectroscopy and Partial Least Squares AnalysisOptical Review, 2003
- Use of the GlucoWatch® biographer in children and adolescents with diabetesPediatric Diabetes, 2002
- Measurement of aqueous glucose in a model anterior chamber using Raman spectroscopyJournal of Raman Spectroscopy, 2002
- Electroanalysis of Glucose in Transcutaneously Extracted SamplesElectroanalysis, 2000
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998
- Biomedical Applications of Raman SpectroscopyJournal of Raman Spectroscopy, 1997
- Influence of glucose concentration on light scattering in tissue-simulating phantomsOptics Letters, 1994
- Suction Blisters of the Skin: A Compartment with Physiological, Interstitium-Like PropertiesScandinavian Journal of Clinical and Laboratory Investigation, 1984
- OPTICAL MONITOR OF GLUCOSEAsaio Journal, 1979
- Suction Blister Device for Separation of Viable Epidermis from Dermis*Journal of Investigative Dermatology, 1968