Fetal pulse oximetry
- 1 February 1996
- journal article
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 75 (2) , 144-148
- https://doi.org/10.3109/00016349609033307
Abstract
Background. During recent years fetal pulse oximetry has been under development for use in monitoring fetal oxygenation during labor. In a methodological study we have tested the practical applicability of one type of sensor (FS-10 Oxisensor, Nellcor®). Both obstetricians and midwives took active part in sensor placement. The readings of fetal arterial oxygen saturation (SpO2) were not taken into account when managing the patients. Methods. Oxygenation was monitored during labor in 96 singleton pregnancies. Mean SpO2 levels were calculated when cervical dilatation was 4-7 cm and 8-10 cm, and in the second stage of labor. Student's t-test was used for paired comparisons. A p-valueResults. Of the 96 oxisensors. 91 (95%) were successfully placed. One mother felt pain which disappeared when the sensor was removed. Two of the newborns manifested an impression mark caused by the sensor, which disappeared completely within a day. No infection or increased bleeding was noted. The mean recording time was 134 minutes. SpO2-values were obtainable during 69% of the recording time. A significant fall of mean SpO2 occurred between the first and second stages of labor. Conclusions. The method seems to be harmless for mother and child, and allows SpO2-values to be obtained during two thirds of the recording period. Further research is needed to evaluate the possible clinical value of the method.Keywords
This publication has 12 references indexed in Scilit:
- Reflexions-Pulsoximetrie - Untersuchungen mit eigenem Mess-SystemBiomedizinische Technik/Biomedical Engineering, 2009
- Artifacts in fetal pulse oximetry: Nonarterial pulsatile signalsAmerican Journal of Obstetrics and Gynecology, 1994
- Artifacts in fetal pulse oximetry: Incomplete sensor-to-skin contactAmerican Journal of Obstetrics and Gynecology, 1994
- The Effect of Monitoring the Fetus with a Pulse Oximeter on Puerperal MorbidityJournal of Obstetrics and Gynaecology, 1994
- Fetal pulse oximetry with the Balloon ProbePublished by Springer Nature ,1994
- Potential benefits of fetal pulse oximetry in the management of fetal arrhythmiaPublished by Springer Nature ,1994
- Relationship between changes in fetal oxygen saturation during second stage of labor and neonatal outcome in cases of abnormal fetal heart ratePublished by Springer Nature ,1994
- Do fetal pulse oximetry readings at delivery correlate with cord blood oxygenation and acidaemia?BJOG: An International Journal of Obstetrics and Gynaecology, 1992
- The effect of caput succedaneum on oxygen saturation measurementsBJOG: An International Journal of Obstetrics and Gynaecology, 1990
- Intra‐Uterine Weight Curves Obtained by UltrasoundActa Obstetricia et Gynecologica Scandinavica, 1986