External finger forces in submaximal five-finger static pinch prehension
- 1 March 1992
- journal article
- research article
- Published by Taylor & Francis in Ergonomics
- Vol. 35 (3) , 275-288
- https://doi.org/10.1080/00140139208967813
Abstract
Small conductive polymer force sensors were attached to the distal phalangeal pads for measuring individual finger forces exerted during submaximal static pinch. A linear force summing strain gauge dynamometer for measuring resultant five-finger pinch force was grasped vertically using a neutral wrist posture. Individual finger forces were measured at fixed total pinch force levels of 10%, 20%, and 30% of maximum voluntary exertion using pinch spans of 45 mm and 65 mm. Total pinch force and individual finger forces were also measured while similarly grasping the dynamometer and supporting fixed weights for 1·0 kg, 1·5 kg, and 2·0 kg loads using pinch spans of 45 mm and 65 mm. The index and middle fingers exerted more than 3 N greater average force than the ring and small fingers for the fixed total pinch force task. No significant individual finger force differences were observed at the 10% maximum voluntary exertion level, however both the index and middle fingers exerted more than 5 N greater force than the ring and small fingers at the 30% maximum voluntary exertion level. The average contribution of the index, middle, ring, and small fingers were 33%, 33%, 17%, and 15%, respectfully, for the fixed total pinch force task. As exertion level increased from 10% to 30%, the contribution of the middle finger was not constant increasing from 25% to 38%. Total pinch force increased from 15 N to 30 N when the load weight increased from 1·0 kg to 2·0 kg. The index finger exerted more than 1 N greater average force than the middle finger, and more than 3 N greater average force than the ring and small fingers during the static lifting task. The average contribution of the index, middle, ring, and small fingers were 35%, 26%, 20%, and 19%, respectfully, for the static lifting task. As load weight increased from 1·0kg to 2·0kg, the contribution of the index finger was not constant, decreasing from 38% to 30%.Keywords
This publication has 14 references indexed in Scilit:
- A conductive polymer sensor for measuring external finger forcesJournal of Biomechanics, 1991
- Tactile sensory monitoring of clinician-applied forces during delivery of newbornsIEEE Transactions on Biomedical Engineering, 1988
- Variation of finger forces in maximal isometric grasp tests on a range of cylinder diametersJournal of Biomedical Engineering, 1987
- Forces in the normal and abnormal handJournal of Orthopaedic Research, 1985
- Isolated Finger Flexion Force—a Methodological StudyThe Hand, 1981
- Measuring hand-grip force, using a new application of strain gaugesMedical & Biological Engineering & Computing, 1981
- Inhibition of individual fingers during grip strength exertionErgonomics, 1981
- A methodology for documenting hand positions and forces during manual workJournal of Biomechanics, 1979
- The influence of wrist position on the force produced by the finger flexorsJournal of Biomechanics, 1975
- Scales of apparent force.Journal of Experimental Psychology, 1959