Using Localization Data from Image Interpretations to Improve Estimates of Performance Accuracy
- 1 April 2000
- journal article
- Published by SAGE Publications in Medical Decision Making
- Vol. 20 (2) , 170-184
- https://doi.org/10.1177/0272989x0002000203
Abstract
A recently developed model uses the localization of abnormalities on images to improve statistical precision in measuring detection accuracy Az, the area below an observer's receiver operating characteristic (ROC) curve for ratings of sampled normal and abnormal cases. This study evaluated that improvement by investigating how much the standard error of estimated Az decreased when the statistical analysis included localization data. Comparisons of analyses with vs without localizations were made for: 1) the estimates of Az from observers' rating ROC curves for nodular lesions on clinical chest films and liver CT scans; 2) the probability of correct choices between paired samples of normal and abnormal cases (equivalent to Az); and 3) the sampling distributions of Az measured in Monte Carlo simulations of 2,000 independent rating experiments. Localization information considerably improved the precision of Az estimates, particularly when detection accuracy was low ( Az ~ 0.60). These data provided roughly the same benefits in estimation precision as would two-to-fourfold increases in the sizes of both 1) the samples of positive and negative cases and 2) the observer samples used to estimate Az means. Key words: ROC analysis; LROC; observer performance accuracy; observer vanability; detection; localization; image interpretation. (Med Decis Making 2000;20:170-185)Keywords
This publication has 17 references indexed in Scilit:
- Computing Sample Size for Receiver Operating Characteristic StudiesInvestigative Radiology, 1994
- Artificial Neural Networks for Single Photon Emission Computed TomographyInvestigative Radiology, 1993
- Visualization and Detection-Localization on Computed Tomographic ImagesInvestigative Radiology, 1991
- Improvement in Radiologists?? Detection of Clustered Microcalcifications on MammogramsInvestigative Radiology, 1990
- Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC StudiesInvestigative Radiology, 1989
- Detection of noisy visual targets: Models for the effects of spatial uncertainty and signal-to-noise ratioPerception & Psychophysics, 1981
- Statistical significance tests for binormal ROC curvesJournal of Mathematical Psychology, 1980
- The area above the ordinal dominance graph and the area below the receiver operating characteristic graphJournal of Mathematical Psychology, 1975
- Some aspects of ROC curve-fitting: Normal and logistic modelsJournal of Mathematical Psychology, 1972
- Maximum-likelihood estimation of parameters of signal-detection theory and determination of confidence intervals—Rating-method dataJournal of Mathematical Psychology, 1969