Positron Emission Tomographic Imaging of the Myocardium with 81Rb
- 1 April 1982
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 6 (2) , 341-349
- https://doi.org/10.1097/00004728-198204000-00020
Abstract
An approach to the assessment of regional myocardial perfusion has been developed utilizing positron emission tomographic imaging of the heart after intravenous administration of 18Rb (T1/2 = 4.6 hr) and a multicrystal positron camera. In five intact anesthetized dogs, 1.0 to 2.0 mCi of 81RbCl was administered and imaging begun 5 min later. A total of 7 to 9 transverse section images of the heart (1 cm thick) were obtained by the computer reconstruction of 208 images taken at uniformly spaced angles as the camera was rotated 180° around the animal. Collection time was 18 min. Emission images of 81Rb activity were corrected for attenuation by first obtaining transmission data using a planar positron-emitting source. Transverse section images through the apex of the heart showed uniform uptake of 81Rb+ activity below the left ventricular (LV) cavity. Tomographic images through the midventricular level showed myocardial 81Rb+ distribution in an annular pattern around the LV cavity, and tomographic cuts through the base of the heart showed a horseshoe appearance of activity anteriorly and diminished tracer uptake posteriorly in the region of the left atrial wall. These studies demonstrate the feasibility of three-dimensional myocardial imaging by using the 33% positron emission of 81Rb+ and a positron camera.This publication has 7 references indexed in Scilit:
- QUANTITATIVE TL-201 EXERCISE SCINTIGRAPHY FOR DETECTION OF CORONARY-ARTERY DISEASE1981
- The dependence of accumulation of 13NH3 by myocardium on metabolic factors and its implications for quantitative assessment of perfusion.Circulation, 1980
- Assessment of Regional Myocardial Perfusion by Positron Emission Tomography after Intracoronary Administration of Gallium-68 Labeled Albumin MicrospheresJournal of Computer Assisted Tomography, 1979
- Detection of remote myocardial infarction in patients with positron emission transaxial tomography and intravenous 11C-palmitate.Circulation, 1977
- Differentiation of transiently ischemic from infarcted myocardium by serial imaging after a single dose of thallium-201.Circulation, 1977
- Noninvasive evaluation of regional myocardial perfusion in 112 patients using a mobile scintillation camera and intravenous nitrogen-13 labeled ammonia.Circulation, 1976
- INTERCOMPARISON OF MYOCARDIAL IMAGING AGENTS - TL-201, CS-129, K-43, AND RB-811976