Abstract
Background— Rotary blood pumps used as left ventricular assist devices (LVADs) allow for long-term support and may become suitable alternatives to heart transplantation. Effects of this technology on the coagulation system are not completely understood, leading to controversial anticoagulation protocols. Thus, we investigated the primary hemostasis in patients with chronic LVAD therapy. Methods and Results— Twenty-six outpatients received axial flow LVAD (HeartMate II; Thoratec) for a median support time of 4.5 months. In a cross-sectional protocol, platelet aggregation in response to ADP and epinephrine, von Willebrand antigen (vWF:AG), and collagen-binding capacity (vWF:CB) were obtained. Von Willebrand factor (vWF) multimer analyses were performed, and patients were screened for bleeding events. This analysis was repeated after removal of the device for transplantation or recovery (n=12) and after a median of 15.5 months in ongoing patients (n=11). In all patients on devices, severe impairment of platelet aggregation as well as a loss of large vWF multimers were found. In 10 patients, a decreased vWF:CB/vWF:AG ratio was observed. Bleeding episodes occurred with an incidence of 0.17 per patient-year. After removal of the device, normal patterns of platelet aggregation, multimer analysis, and vWF:CB/vWF:AG ratio were recorded. In the second analysis of ongoing patients, impairment of platelet aggregation and loss of large vWF multimers were verified. Conclusions— A diagnosis of von Willebrand syndrome type 2 was established in all patients after LVAD implantation, and bleeding events confirmed this finding. Reversibility of this condition was found after removal of the device.Keywords
This publication has 26 references indexed in Scilit:
- Increased Leukocyte-Platelet Interactions During Circulatory Support With Left Ventricular Assist DevicesAsaio Journal, 2009
- Platelet Dysfunction in Outpatients With Left Ventricular Assist DevicesThe Annals of Thoracic Surgery, 2009
- HeartMate II left ventricular assist device; early European experienceEuropean Journal of Cardio-Thoracic Surgery, 2008
- Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease☆European Journal of Cardio-Thoracic Surgery, 2008
- Functional imaging of shear-dependent activity of ADAMTS13 in regulating mural thrombus growth under whole blood flow conditionsBlood, 2008
- Diagnostic workup of patients with acquired von Willebrand syndrome: a retrospective single‐centre cohort studyJournal of Thrombosis and Haemostasis, 2008
- Intravenous DDAVP and Factor VIII-von Willebrand Factor Concentrate for the Treatment and Prophylaxis of Bleedings in Patients With von Willebrand Disease Type 1, 2 and 3Clinical and Applied Thrombosis/hemostasis, 2007
- Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist deviceThe Journal of Heart and Lung Transplantation, 2005
- Platelet activation and aggregation profile in prolonged external ventricular supportThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Implantable left ventricular assist device for treatment of pulmonary hypertension in candidates for orthotopic heart transplantation—a preliminary study1European Journal of Cardio-Thoracic Surgery, 2004