Rapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging
- 10 July 2000
- journal article
- research article
- Published by Wiley in Human Brain Mapping
- Vol. 10 (4) , 204-211
- https://doi.org/10.1002/1097-0193(200008)10:4<204::aid-hbm60>3.0.co;2-2
Abstract
The well‐known variability in the distribution of high frequency electromagnetic fields in the human body causes problems in the analysis of structural information in high field magnetic resonance images. We describe a method of compensating for the purely intensity‐based effects. In our simple and rapid correction algorithm, we first use statistical means to determine the background image noise level and the edges of the image features. We next populate all “noise” pixels with the mean signal intensity of the image features. These data are then smoothed by convolution with a gaussian filter using Fourier methods. Finally, the original data that are above the noise level are normalized to the smoothed images, thereby eliminating the lowest spatial frequencies in the final, corrected data. Processing of a 124 slice, 256 × 256 volume dataset requires under 70 sec on a laptop personal computer. Overall, the method is less prone to artifacts from edges or from sensitivity to absolute head position than are other correction techniques. Following intensity correction, the images demonstrated obvious qualitative improvement and, when subjected to automated segmentation tools, the accuracy of segmentation improved, in one example, from 35.3% to 84.7% correct, as compared to a manually‐constructed gold standard. Hum. Brain Mapping 10:204–211, 2000.Keywords
This publication has 15 references indexed in Scilit:
- Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRIIEEE Transactions on Medical Imaging, 1998
- Estimating the bias field of MR imagesIEEE Transactions on Medical Imaging, 1997
- A method to create an optimum current distribution and homogeneous B1 field for elliptical birdcage coilsMagnetic Resonance in Medicine, 1997
- Image feature based automatic correction of low-frequency spatial intensity variations in MR imagesMagnetic Resonance Imaging, 1997
- Local histogram correction of MRI spatially dependent image pixel intensity nonuniformityJournal of Magnetic Resonance Imaging, 1996
- Sources of intensity nonuniformity in spin echo images at 1.5 TMagnetic Resonance in Medicine, 1994
- Magnetic Resonance Imaging Morphometric Analysis of Cerebral Volume Loss in Human Immunodeficiency Virus InfectionArchives of Neurology, 1993
- Rapid NMR imaging of dynamic processes using the FLASII techniqueMagnetic Resonance in Medicine, 1986
- An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 TJournal of Magnetic Resonance (1969), 1985
- Application of Fourier Transform Spectroscopy to Magnetic ResonanceReview of Scientific Instruments, 1966